A New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee Joint
- 1 November 1995
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 117 (4) , 373-382
- https://doi.org/10.1115/1.2794195
Abstract
This paper describes the design and accuracy evaluation of a new six degree of freedom load application system for in vitro testing of the human knee joint. External loads of both polarity in all six degrees of freedom can be applied either individually or in any combination while the knee is permitted to move unconstrained in response to applied loads. The flexion/extension degree of freedom permits the full physiological range of motion. In addition to external loads, forces of the three major muscle groups (quadriceps, hamstrings, gastrocnemius) crossing the joint can be developed. Full automation and rapid convergence of loads to programmed values are achieved through a computer which feeds command signals to servo controller/electro-pneumatic servo valves. The servo valves regulate pressure to pneumatic actuators which develop the various loads. Experiments undertaken to quantify the accuracy of both load and displacement measurements reveal that errors particularly in load measurement are effectively controlled through the apparatus design.Keywords
This publication has 25 references indexed in Scilit:
- The Use of Robotics Technology to Study Human Joint Kinematics: A New MethodologyJournal of Biomechanical Engineering, 1993
- Design and Development of an Unconstrained Dynamic Knee SimulatorJournal of Biomechanical Engineering, 1993
- The Effects of Knee Motion and External Loading on the Length of the Anterior Cruciate Ligament (ACL): A Kinematic StudyJournal of Biomechanical Engineering, 1991
- Simultaneous Measurement of Changes in Length of the Cruciate Ligaments During Knee MotionPublished by Wolters Kluwer Health ,1991
- Implementation of a Five Degree of Freedom Automated System to Determine Knee Flexibility In VitroJournal of Biomechanical Engineering, 1990
- Modeling Forces on the Anterior Cruciate Knee Ligament During Backward Falls While SkiingPublished by ASTM International ,1989
- Skier Injury TrendsPublished by ASTM International ,1989
- Description and Error Evaluation of an In Vitro Knee Joint Testing SystemJournal of Biomechanical Engineering, 1988
- Isobutyl Cyanoacrylate as a Soft Tissue AdhesiveClinical Orthopaedics and Related Research, 1988
- The envelope of passive knee joint motionJournal of Biomechanics, 1988