Sampling Trace‐Level Organic Solutes with Polymeric Tubing Part I. Static Studies
- 1 November 1997
- journal article
- Published by Wiley in Ground Water Monitoring & Remediation
- Vol. 17 (4) , 115-124
- https://doi.org/10.1111/j.1745-6592.1997.tb01271.x
Abstract
Twenty polymeric tubings were filled with a test solution containing eight organic solutes. The test solutions were monitored for losses, indicating that sorption had occurred, and for signs that leaching of organic constituents had occurred. The tubings tested included seven flexible products and eight fluoropolymers. Among the rigid tubings tested, three fluoropolymers (fluorinated ethylene propylene [FEP], FEP‐lined polyethylene, polyvinylidene fluoride) were the least sorptive tubings. However, even these tubings readily sorbed some of the analytes. Among the flexible tubings tested, a fluoroelastomer tubing and a tubing made of a copolymer of vinylidene fluoride and hexafluoropropylene were the least sorptive.Several of the tubings tested leached constituents into the test solution. The polyurethane, polyamide, flexible polyvinyl chloride (PVC), polyester‐lined PVC, and silicone‐modified thermoplastic elastomer tubings were found to leach the most constituents. We were unable to detect any constituents leaching from the polyethylene tubings, the rigid fluoropolymer tubings, and one of the plasticized polypropylene tubings.Keywords
This publication has 12 references indexed in Scilit:
- Contamination of Ground Water Samples from Well InstallationsEnvironmental Technology, 1996
- Effect of Concentration on Sorption of Dissolved Organics by PVC, PTFE, and Stainless Steel Well CasingsGround Water Monitoring & Remediation, 1994
- Modeling the Equilibrium Partitioning of Organic Contaminants between PTFE, PVC, and GroundwaterEnvironmental Science & Technology, 1994
- Influence of Casing Materials on Trace‐Level Chemicals in Well WaterGround Water Monitoring & Remediation, 1990
- Sorption of Aromatic Hydrocarbons by Materials Used in Construction of Ground-Water Sampling WellsPublished by ASTM International ,1990
- Effects of Selected Sampling Equipment and Procedures on the Concentrations of Trichloroethylene and Related Compounds in Ground Water SamplesGround Water Monitoring & Remediation, 1987
- Sampling Tubing Effects on Groundwater SamplesAnalytical Chemistry, 1985
- Effect of sampling variables on recovery of volatile organics in waterJournal AWWA, 1983
- LEACHING OF TRACE ORGANICS INTO WATER FROM FIVE COMMON PLASTICSGround Water Monitoring & Remediation, 1983
- Contamination of water by synthetic polymer tubesEnvironmental Science & Technology, 1974