Comparison of Immediate and Intermediate-Term Results of Intravascular Ultrasound Versus Angiography-Guided Palmaz-Schatz Stent Implantation in Matched Lesions
Open Access
- 4 November 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 96 (9) , 2997-3005
- https://doi.org/10.1161/01.cir.96.9.2997
Abstract
Background Intravascular ultrasound (IVUS) provides more precise information than angiography about vascular dimensions. This information is used by some centers to optimize intracoronary stent implantation. There are no direct comparisons of the effects on restenosis of optimal IVUS-guided versus angiography-directed high-pressure stenting. Methods and Results Lesions of patients who had a 6-month angiographic follow-up study were eligible for matching. From 445 consecutive lesions treated by Palmaz-Schatz (P-S) stenting guided by IVUS (IVUS group) in Milan, 173 lesions were individually matched with 173 of 476 consecutive lesions treated by P-S stenting directed by angiography (Angio group) in Hamburg. Lesions were selected by a computerized program according to baseline clinical, angiographic, and procedural variables. Immediate and 6-month angiographic results were retrospectively compared, distinguishing an “early phase” from a “late phase.” This distinction was based on the more aggressive dilation strategy with larger balloons and more demanding IVUS criteria for optimal stent expansion used in Milan in the early phase. In both phases, a larger minimum lumen diameter (MLD) immediately after stenting and after 6 months was achieved in the IVUS group than in the Angio group. In the early phase, the dichotomous restenosis rate was lower in the IVUS group than in the Angio group (9.2% versus 22.3%; P =.04). In the late phase, there was no difference in restenosis between the groups (22.7% versus 23.7%; P =1.0). Conclusions In matched lesions treated with high-pressure stenting, IVUS guidance achieved a larger MLD than angiographic guidance. However, in the IVUS group, the restenosis rate was lower only in the early phase, when balloons larger than currently used were selected to maximize the stent lumen area.Keywords
This publication has 10 references indexed in Scilit:
- Intracoronary stenting without intravascular ultrasound guidance followed by antiplatelet therapy with aspirin alone in selected patientsThe American Journal of Cardiology, 1996
- Matching to guide the design and predict the outcome of randomized atherectomy trialsAmerican Heart Journal, 1995
- Intravascular ultrasound after low and high inflation pressure coronary artery stent implantationJournal of the American College of Cardiology, 1995
- Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound GuidanceCirculation, 1995
- Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stentsJournal of the American College of Cardiology, 1994
- Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomyJournal of the American College of Cardiology, 1993
- Intravascular ultrasound imaging: In vitro validation and pathologic correlationJournal of the American College of Cardiology, 1990
- Proposal for a simple synthesis prognostic staging system in chronic myelogenous leukemiaThe American Journal of Medicine, 1990
- Impact of compensatory enlargement of atherosclerotic coronary arteries on angiographic assessment of coronary artery disease.Circulation, 1989
- A new digital electronic caliper for measurement of coronary arterial stenosis: Comparison with visual estimates and computer-assisted measurementsThe American Journal of Cardiology, 1984