Flashover of contaminated nonceramic outdoor insulators in a wet atmosphere
- 1 December 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 5 (6) , 814-823
- https://doi.org/10.1109/94.740762
Abstract
This paper deals with the flashover mechanism and performance of contaminated nonceramic (also known as composite and polymeric) outdoor insulators under wet conditions. Two types of wetting that occur in service, namely fog and rain, were considered. Different profiles of line insulators having weathersheds made from material families such as, high temperature vulcanizing (HTV) silicone rubber (SR) and ethylene propylene (EP) diene monomer rubber, were evaluated. The results demonstrate that the performance, and hence the relative ranking of nonceramic line insulators is influenced by the wetting mode and insulator geometry; that flashover of contaminated insulators can occur with rain at a much lower contamination severity than with fog; and that the mechanism of contamination flashover under rain is significantly different from that under fog condensation. New insulator profiles have been identified and tested to show that they can provide improved flashover performance, when compared to existing designs. This work proves that a comprehensive evaluation of outdoor insulator performance can be obtained by performing flashover tests that include more than one form of wetting, and hence illustrates the limitations of current standard contamination tests that employ only one form of insulator wetting.Keywords
This publication has 18 references indexed in Scilit:
- Modeling of altitude effects on AC flashover of polluted high voltage insulatorsIEEE Transactions on Power Delivery, 1997
- Electrical performance of non-ceramic insulators in artificial contamination tests. Role of resting timeIEEE Transactions on Dielectrics and Electrical Insulation, 1996
- The AC-behavior of a hydrophilic and hydrophobic post insulator during rainIEEE Transactions on Power Delivery, 1994
- Mechanism of HVDC wall bushing flashover in nonuniform rainIEEE Transactions on Power Delivery, 1991
- Insulators for High VoltagesPublished by Institution of Engineering and Technology (IET) ,1988
- The Booster Shed: Prevention of Flashover of Polluted Substation Insulators in Heavy WettingIEEE Transactions on Power Apparatus and Systems, 1978
- Formation Mechanisms of Clean Zones During the Surface Flashover of Contaminated InsulatorsIEEE Transactions on Electrical Insulation, 1978
- A Study on Dynamic Voltage Distribution on Contaminated Insulator SurfaceIEEE Transactions on Power Apparatus and Systems, 1973
- Effect of pollution on high-voltage outdoor insulatorsProceedings of the Institution of Electrical Engineers, 1971
- Growth of discharges on polluted insulationProceedings of the Institution of Electrical Engineers, 1963