Routine ultrasound examination at 12 or 18 gestational weeks for prenatal detection of major congenital heart malformations? A randomised controlled trial comprising 36 299 fetuses
- 18 May 2006
- journal article
- research article
- Published by Wiley in BJOG: An International Journal of Obstetrics and Gynaecology
- Vol. 113 (6) , 675-682
- https://doi.org/10.1111/j.1471-0528.2006.00951.x
Abstract
Objective To compare the rate of prenatal diagnosis of heart malformations between two policies of screening for heart malformations. Design Randomised controlled trial. Setting Six university hospitals, two district general hospitals. Sample A total of 39 572 unselected pregnancies randomised to either policy. Methods The 12‐week policy implied one routine scan at 12 weeks including measurement of nuchal translucency (NT), and the 18‐week policy implied one routine scan at 18 weeks. Fetal anatomy was scrutinised using the same check‐list in both groups, and in both groups, indications for fetal echocardiography were ultrasound findings of any fetal anomaly, including abnormal four‐chamber view, or other risk factors for heart malformation. In the 12‐week scan group, NT ≥3.5 mm was also an indication for fetal echocardiography. Main outcome measure Prenatal diagnosis of major congenital heart malformation. Results In the 12‐week scan group, 7 (11%) of 61 major heart malformations were prenatally diagnosed versus 9 (15%) of 60 in the 18‐week scan group (P= 0.60). In four (6.6%) women in the 12‐week scan group, the routine scan was the starting point for investigations resulting in a prenatal diagnosis versus in 9 (15%) women in the 18‐week scan group (P= 0.15). The diagnosis was made ≤22 weeks in 5% (3/61) of the cases in the 12‐week scan group versus in 15% (9/60) in the 18‐week scan group (P= 0.08). Conclusions The prenatal detection rate of major heart malformations was low with both policies. The 18‐week scan policy seemed to be superior to the 12‐week scan policy, although the differences in prenatal detection rates were not statistically significant.Keywords
This publication has 32 references indexed in Scilit:
- Prenatal diagnosis of coarctation of the aorta improves survival and reduces morbidityHeart, 2002
- Improved Surgical Outcome After Fetal Diagnosis of Hypoplastic Left Heart SyndromeCirculation, 2001
- Detection of Transposition of the Great Arteries in Fetuses Reduces Neonatal Morbidity and MortalityCirculation, 1999
- Efficacy of Routine Fetal Ultrasound Screening for Congenital Heart Disease in Normal PregnancyCirculation, 1996
- Incidence of congenital heart disease: I. Postnatal incidencePediatric Cardiology, 1995
- Prospective diagnosis of 1,006 consecutive cases of congenital heart disease in the fetusJournal of the American College of Cardiology, 1994
- Value of routine ultrasound scanning at 19 weeks: a four year study of 8849 deliveries.BMJ, 1992
- CONGENITAL HEART DISEASE: PREVALENCE AT LIVEBIRTHAmerican Journal of Epidemiology, 1985
- Incidence of cardiac malformations at birth and later, and neonatal mortality.Heart, 1973
- Congenital Heart Disease in 56,109 Births Incidence and Natural HistoryCirculation, 1971