Energy dependence of scatter components in multispectral PET imaging
- 1 March 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 14 (1) , 138-145
- https://doi.org/10.1109/42.370410
Abstract
High resolution images in PET based on small individual detectors are obtained at the cost of low sensitivity and increased detector scatter. These limitations can be partially overcome by enlarging discrimination windows to include more low-energy events and by developing more efficient energy-dependent methods to correct for scatter radiation from all sources. The feasibility of multispectral scatter correction was assessed by decomposing response functions acquired in multiple energy windows into four basic components: object, collimator and detector scatter, and trues. The shape and intensity of these components are different and energy-dependent. They are shown to contribute to image formation in three ways: useful (true), potentially useful (detector scatter), and undesirable (object and collimator scatter) information to the image over the entire energy range. With the Sherbrooke animal PET system, restoration of detector scatter in every energy window would allow nearly 90% of all detected events to participate in image formation. These observations suggest that multispectral acquisition is a promising solution for increasing sensitivity in high resolution PET. This can be achieved without loss of image quality if energy-dependent methods are made available to preserve useful events as potentially useful events are restored and undesirable events removed.Keywords
This publication has 17 references indexed in Scilit:
- Design and engineering aspects of a high resolution positron tomograph for small animal imagingIEEE Transactions on Nuclear Science, 1994
- Normalization of multispectral data in positron emission tomographyPhysics in Medicine & Biology, 1993
- A PET camera simulator with multispectral data acquisition capabilitiesIEEE Transactions on Nuclear Science, 1993
- Source distribution dependent scatter correction for PVIIEEE Transactions on Nuclear Science, 1993
- Two new strategies to increase the signal to noise ratio in positron volume imagingIEEE Transactions on Nuclear Science, 1993
- Scatter correction in the transaxial slices of a whole-body positron emission tomographPhysics in Medicine & Biology, 1993
- The problem of scatter correction in positron volume imagingIEEE Transactions on Medical Imaging, 1993
- PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systemsPhysics in Medicine & Biology, 1992
- Compton scattering in a large-aperture positron imaging systemIEEE Transactions on Medical Imaging, 1988
- Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the ProjectionsJournal of Computer Assisted Tomography, 1983