Miniaturized movable contactless conductivity detection cell for capillary electrophoresis
- 8 July 2003
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 24 (12-13) , 2144-2149
- https://doi.org/10.1002/elps.200305475
Abstract
A miniaturized capacitively coupled contactless conductivity detector (mini-C4D) cell has been designed which is small enough to allow it to slide along the effective capillary length inside the capillary cassette of an Agilent capiillary electrophoresis system (CE) (or other CE brand of similar construction), including the possibility of positioning it close to the point of optical detection (4 cm), or even putting two such detector cells in one cassette. The cell was tested and the performance characteristics (noise, sensitivity, and peak width) were compared with those obtained with the previously used large C4D cell. No significant differences were observed. The mini-C4D was used in simultaneous separations of common cations and anions where its advantage over a larger C4D cell is the ability to vary the point of detection with the mini-C4D cell continuously at any point along the capillary length, so that the optimum apparent selectivity can be chosen. Other applications include providing a convenient second point of detection in addition to photometric detection, such as to measure accurately the linear velocity of a zone, or to allow placement of two mini-C4D cells in one capillary cassette simultaneously.Keywords
This publication has 19 references indexed in Scilit:
- On-Chip Contactless Four-Electrode Conductivity Detection for Capillary Electrophoresis DevicesAnalytical Chemistry, 2002
- Simultaneous separation of inorganic anions and cations using capillary electrophoresis with a movable contactless conductivity detectorThe Analyst, 2002
- On-Column Ion-Exchange Preconcentration of Inorganic Anions in Open Tubular Capillary Electrochromatography with Elution Using Transient-Isotachophoretic Gradients. 3. Implementation and Method DevelopmentAnalytical Chemistry, 2002
- Improved capacitively coupled conductivity detector for capillary electrophoresisThe Analyst, 2002
- Dual photometric-contactless conductometric detector for capillary electrophoresisAnalytica Chimica Acta, 2001
- On-Capillary Ion-Exchange Preconcentration of Inorganic Anions in Open-Tubular Capillary Electrochromatography with Elution Using Transient-Isotachophoretic Gradients. 2. Characterization of the Isotachophoretic GradientAnalytical Chemistry, 2001
- On-capillary ion-exchange preconcentration of inorganic anions using open-tubular capillaries followed by elution with a transient isotachophoretic gradientThe Analyst, 2000
- Capillary Modification by Noncovalent Polycation Adsorption: Effects of Polymer Molecular Weight and Adsorption Ionic StrengthAnalytical Chemistry, 1999
- An Oscillometric Detector for Capillary ElectrophoresisAnalytical Chemistry, 1998
- Contactless Conductivity Detection for Capillary ElectrophoresisAnalytical Chemistry, 1998