Abstract
The catastrophic failure of Hinkley Point ‘A’ unit No. 5 in September 1969 was the result of spontaneous brittle fracture of a shrunk-on ***l.p. turbine disc, initiated by stress-corrosion cracking in the crown of a keyway in the disc bore. Stress corrosion cracking of disc bores and keyways was also found on a number of other discs. The discs were made of 3 Cr-Mo steel and complied with normal acceptance standards, but due to temper embrittlement, their fracture toughness was low, and cracks only about 1/16 in deep in the concentrated stress field at the keyway crown were large enough to initiate brittle fracture. Investigation of the cause of the stress-corrosion cracking is being separately reported.Keywords
This publication has 7 references indexed in Scilit:
- Investigation into the Consequences of the Failure of a Turbine-Generator at Hinkley Point ‘A’ Power StationProceedings of the Institution of Mechanical Engineers, 1972
- Spin tests to determine brittle fracture under plane strainExperimental Mechanics, 1968
- Burst Strength of Rotating DiscsProceedings of the Institution of Mechanical Engineers, 1965
- Application of the Griffith-Irwin Theory of Crack Propagation to the Bursting Behavior of Disks, Including Analytical and Experimental StudiesTransactions of the American Society of Mechanical Engineers, 1958
- Failure of a 60-MW Steam Turbo-Generator at Uskmouth Power StationProceedings of the Institution of Mechanical Engineers, 1958
- Investigation of Large Steam-Turbine Spindle FailureTransactions of the American Society of Mechanical Engineers, 1956
- Report of the Investigation of Two Generator Rotor FracturesTransactions of the American Society of Mechanical Engineers, 1956