Electrical Induction of Ventricular Fibrillation in the Human Heart
- 1 January 1976
- journal article
- Published by Taylor & Francis in Scandinavian Journal of Thoracic and Cardiovascular Surgery
- Vol. 10 (3) , 237-240
- https://doi.org/10.3109/14017437609167800
Abstract
An experimental study was made on induction thresholds for ventricular fibrillation with alternating currents at frequencies ranging between 6 and 1 600 c/s. The tests were performed on experimental dogs and on patients in association with open-heart surgery. The most vulnerable range was found to be between 12 and 60 c/s. A close similarity was demonstrated between canine and human hearts. The induction of ventricular fibrillation during open-heart surgery is discussed. Ventricular fibrillation, caused by electricity, is either accidental or deliberately induced for medical purposes. The myocardial threshold of excitability towards alternating currents is dependent on two parameters, current and frequency. The vulnerability of the heart towards current has been thoroughly investigated by several authors (Walter, 1969; Dalziel & Lee, 1969; Nickel & Spang, 1965; Kugelberg, 1975). A frequency of 50–60 c/s was utilized in all these determinations, as this is the one of choice in networks for distribution of electric power all over the world. Thus, accidental ventricular fibrillation is most likely to occur with currents of this frequency, and inductions for medical purposes, i.e. during open-heart operations, are achieved in the easiest way with simple transformers delivering the same frequency.Keywords
This publication has 9 references indexed in Scilit:
- Accidental Ventricular Fibrillation of the Human Heart:A Study of Excitability Levels with Alternating CurrentScandinavian Journal of Thoracic and Cardiovascular Surgery, 1975
- Studies of the effects of ventricular fibrillation on the adequacy of regional myocardial flowThe Journal of Thoracic and Cardiovascular Surgery, 1974
- Studies of the effects of ventricular fibrillation on the adequacy of regional myocardial flowThe Journal of Thoracic and Cardiovascular Surgery, 1974
- Studies of the effects of ventricular fibrillation on the adequacy of regional myocardial flowThe Journal of Thoracic and Cardiovascular Surgery, 1974
- Threshold 60-Hz Current Required for Ventricular Fibrillation in Subjects of Various Body WeightsIEEE Transactions on Biomedical Engineering, 1973
- Induced ischemic arrestThe Journal of Thoracic and Cardiovascular Surgery, 1972
- Shock Hazards in Operating Rooms and Patient-care AreasAnesthesiology, 1969
- Hazards in the use of low frequencies for the measurement of physiological events by impedanceMedical & Biological Engineering & Computing, 1969
- Lethal electric currentsIEEE Spectrum, 1969