Dual-Source CT Coronary Angiography: Image Quality, Mean Heart Rate, and Heart Rate Variability
- 1 September 2007
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 189 (3) , 567-573
- https://doi.org/10.2214/ajr.07.2078
Abstract
OBJECTIVE. The purpose of this study was to evaluate the effect of mean heart rate and heart rate variability on the image quality of dual-source CT coronary angiography.SUBJECTS AND METHODS. Eighty patients underwent dual-source CT coronary angiography. Thirteen data sets were reconstructed in 5% steps from 20-80% of the R-R interval. Heart rate variability was calculated as SD of mean heart rate. Two independent blinded reviewers assessed the image quality of each segment.RESULTS. Mean heart rate was 65.3 ± 13.9 (SD) beats per minute (bpm) (range, 35-99 bpm) with a variability of 3.4 ± 4.1 bpm (range, 0.4-17.5 bpm). Image quality was sufficient for diagnosis for 97.8% (1,043/1,066) of arterial segments. No significant correlation was found between mean heart rate and image quality in any segment or any coronary artery. No significant correlation was found between heart rate variability and image quality in any segment, the right coronary artery, or the left anterior descending artery, but there was a si...Keywords
This publication has 28 references indexed in Scilit:
- ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 Appropriateness Criteria for Cardiac Computed Tomography and Cardiac Magnetic Resonance Imaging⁎⁎Developed in accordance with the principles and methodology outlined by ACCF: Patel MR, Spertus JA, Brindis RG, Hendel RC, Douglas PS, Peterson ED, Wolk MJ, Allen JM, Raskin IE. ACCF proposed method for evaluating the appropriateness of cardiovascular imaging. J Am Coll Cardiol 2005;46:1606–13.Journal of the American College of Cardiology, 2006
- Accuracy of 64-MDCT in the Diagnosis of Ischemic Heart DiseaseAmerican Journal of Roentgenology, 2006
- Cardiac Imaging 2006American Journal of Roentgenology, 2006
- High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary AngiographyCirculation, 2005
- Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed TomographyJournal of the American College of Cardiology, 2005
- Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed TomographyJournal of the American College of Cardiology, 2005
- Accuracy of MSCT coronary angiography with 64-slice technology: first experienceEuropean Heart Journal, 2005
- Accuracy of thin-slice computed tomography in the detection of coronary stenosesEuropean Heart Journal, 2004
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- ECG-gated Reconstructed Multi–Detector Row CT Coronary Angiography: Effect of Varying Trigger Delay on Image QualityRadiology, 2001