Preliminary results of 200 MeV bunching experiments

Abstract
The AGS was apertured down to a small value, and the injected beam was bunched as abruptly as possible. An instantaneous current was measured corresponding to delta nu/sup 2/ approximately equal to 30. This corresponds to an instantaneous tune shift of approximately 1.9 units, or about 7.5 times the ''classical'' space charge limit. No intensity dependant losses were observed. The instantaneous current was limited by the energy spread in the injected beam.