Mortality and Morbidity Associated With Pressure- and Volume-Limited Infant Ventilators
- 1 September 1978
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Pediatrics & Adolescent Medicine
- Vol. 132 (9) , 865-869
- https://doi.org/10.1001/archpedi.1978.02120340041007
Abstract
• The effect of pressure-limited (PL) and volume-limited (VL) ventilation on mortality and morbidity in infants with severe hyaline membrane disease (HMD) was examined in a prospective controlled study. Criteria for mechanical ventilation were Pao2 value of 50 mm Hg or less or a Paco2 value of 70 mm Hg or greater, while the infant was receiving nasal continuous positive airway pressure (CPAP) at oxygen concentrations (FIO2) of 0.8 or greater and CPAP of 8 cm H2O or greater; HMD associated with severe perinatal asphyxia requiring mechanical ventilation in the delivery room. Consecutive patients were alternately assigned to receive either PL or VL ventilation. Twenty infants were ventilated with PL machines using low peak inspiratory pressures (mean maximum inspiratory pressure of 28 cm H2O) and prolonged inspiratory times. Twenty other infants were ventilated with VL machines, using essentially unlimited peak inspiratory pressures (mean maximum inspiratory pressure of 62 cm H2O) and prolonged expiratory times. There were no significant differences in survival, incidence of pneumothorax or pulmonary interstitial emphysema, or noteworthy bronchopulmonary dysplasia. (Am J Dis Child 132:865-869, 1978)This publication has 7 references indexed in Scilit:
- Chronic Pulmonary Disease in Neonates After Artificial Ventilation: Distribution of Ventilation and Pulmonary Interstitial EmphysemaPediatrics, 1977
- Improved prognosis of infants mechanically ventilated for hyaline membrane diseaseArchives of Disease in Childhood, 1974
- Methods for improving oxygenation in infants mechanically ventilated for severe hyaline membrane disease.Archives of Disease in Childhood, 1973
- Effect of Alterations in Mechanical Ventilator Settings on Pulmonary Gas Exchange in Hyaline Membrane DiseaseArchives of Disease in Childhood, 1971
- Radiographic Features of Pulmonary Oxygen Toxicity in the Newborn: Bronchopulmonary DysplasiaRadiology, 1968
- THE EFFECT OF VARYING INSPIRATORY GAS FLOW RATE ON ARTERIAL OXYGENATION DURING IPPV IN THE RESPIRATORY DISTRESS SYNDROMEBritish Journal of Anaesthesia, 1968
- Pulmonary Disease Following Respirator Therapy of Hyaline-Membrane DiseaseNew England Journal of Medicine, 1967