Mixed Venous Oxygen Saturation as a Promising Parameter for Physiologic Control of Total Artificial Heart
- 1 November 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 46 (6) , 761-766
- https://doi.org/10.1097/00002480-200011000-00020
Abstract
Mixed venous oxygen saturation (SvO2) has been proposed as one of the suitable parameters for physiologic control of a total artificial heart (TAH). To establish the practical application of SvO2, we investigated the response of cardiac output (CO) and SvO2 to step-loaded exercise. A normal calf was surgically equipped with an ultrasonic flowmeter probe and an oximetry catheter in the pulmonary artery to measure CO and SvO2, respectively. Three stage step treadmill exercise tests (1, 2, and 4 km/h) were performed three times. While CO increased from 8.9 L/min at preexercise level to 9.7, 10.2 and 11.4 L/min at 1, 2, and 4 km/h, respectively, SvO2 decreased from 59.6% to 56.8, 55.3, and 52.2%, respectively. There existed a linear correlation between the magnitude of changes in CO and SvO2. CO and SvO2 exhibited a similar course of change, expressing an inverted exponential curve. The time constant of SvO2 was from 19 to 35 seconds, whereas that of CO was from 21 to 39 seconds. We conclude that SvO2 changes in close association with CO during exercise and has good potential to be a parameter for physiologic control of a TAH, by reflecting the recipient’s CO demand without conspicuous time delay.Keywords
This publication has 12 references indexed in Scilit:
- Progress of an Electrohydraulic Total Artificial Heart System with a Separate Energy ConverterAsaio Journal, 1999
- The Development of a Control Method for a Total Artificial Heart Using Mixed Venous Oxygen SaturationArtificial Organs, 1999
- Characterization and Optimization of the Flow Pattern Inside a Diaphragm Blood Pump Based on Flow Visualization TechniquesAsaio Journal, 1998
- CHARACTERISTICS OF MIXED VENOUS OXYGEN SATURATION (SvO2) AND PHYSICAL ACTIVITY (PhyAc) AS PARAMETERS FOR ARTIFICIAL HEART CONTROLAsaio Journal, 1997
- Set-up, Improvement, and Evaluation of an Electrohydraulic Total Artificial Heart With a Separately Placed Energy ConverterPublished by Wolters Kluwer Health ,1996
- Development of an Electrohydraulic Total Artificial Heart at the National Cardiovascular Center, Osaka, JapanAsaio Journal, 1995
- Continuous In‐Line Monitoring of Oxygen Delivery to Control Artificial Heart OutputArtificial Organs, 1990
- Abrupt changes in mixed venous blood gas composition after the onset of exerciseJournal of Applied Physiology, 1989
- A miniature hybrid reflection type optical sensor for measurement of hemoglobin content and oxygen saturation of whole bloodIEEE Transactions on Biomedical Engineering, 1988
- EXTRINSIC ARTIFICIAL HEART CONTROL VIA MIXED VENOUS BLOOD GAS TENSION ANALYSISAsaio Journal, 1973