Venous stasis and routine hematologic testing
- 1 October 2006
- journal article
- research article
- Published by Wiley in Clinical and Laboratory Haematology
- Vol. 28 (5) , 332-337
- https://doi.org/10.1111/j.1365-2257.2006.00818.x
Abstract
Prolonged venous stasis, as generated by a long tourniquet placement, produces spurious variations in several measurable analytes. To verify to what extent venous stasis influences routine hematologic testing, we assessed routine hematologic parameters, including hemoglobin, hematocrit, red blood cell count (RBC), main cell hemoglobin (MHC), main cell volume (MCV), platelet count (PLT), main platelet volume (MPV), white blood cell count (WBC) and WBC differential on the Advia 120 automated hematology analyzer in 30 healthy volunteers, either without venous stasis (no stasis) or after application of a 60 mmHg standardized external pressure by a sphygmomanometer, for 1 (1-min stasis) and 3 min (3-min stasis). Although the overall correlation between measures was globally acceptable, the mean values for paired samples were significantly different in all parameters tested, except MCV, MHC, PLT, MPV, eosinophils, basophils and large unstained cells after 1-min stasis and all parameters except MCV, MHC, MPV and basophils after 3-min venous stasis. As expected RBC, hemoglobin and hematocrit displayed a significant trend towards increase, whereas WBC and the WBC subpopulations were decreased. Difference between measurements by Bland and Altman plots exceeded the current analytical quality specifications for desirable bias for WBC, RBC, hemoglobin, hematocrit, lymphocytes and monocytes in samples collected after either 1- and 3-min stasis. These results provide clear evidence that venous stasis during venipuncture might produce spurious and clinically meaningful biases in the measurement of several hematologic parameters, prompting further considerations on the usefulness of adopting appropriate preventive measures for minimizing such influences.Keywords
This publication has 18 references indexed in Scilit:
- Prediction of Hospital Mortality Rates by Admission Laboratory TestsClinical Chemistry, 2006
- Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzerJournal of Laboratory and Clinical Medicine, 2005
- Guidelines for the diagnosis, investigation and management of polycythaemia/erythrocytosisBritish Journal of Haematology, 2005
- Performance Evaluation of the ADVIA 2120 Hematology Analyzer: An International Multicenter Clinical TrialLaboratory Hematology, 2005
- Standardization in laboratory medicine: New challengesClinica Chimica Acta; International Journal of Clinical Chemistry, 2005
- Influence of short-term venous stasis on clinical chemistry testingcclm, 2005
- Quality specification in haematology: the automated blood cell countClinica Chimica Acta; International Journal of Clinical Chemistry, 2004
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- Effect of blood flow on the leukocyte-endothelium interaction in pulmonary microvessels.American Journal of Respiratory and Critical Care Medicine, 1995
- Effects of hydrodynamics and leukocyte-endothelium specificity on leukocyte-endothelium interactionsMicrovascular Research, 1992