Electromyogram amplitude estimation with adaptive smoothing window length
- 1 June 1999
- journal article
- clinical trial
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 46 (6) , 717-729
- https://doi.org/10.1109/10.764948
Abstract
Typical electromyogram (EMG) amplitude estimators use a fixed window length for smoothing the amplitude estimate. When the EMG amplitude is dynamic, previous research suggests that varying the smoothing length as a function of time may improve amplitude estimation. This paper develops optimal time-varying selection of the smoothing window length using a stochastic model of the EMG signal. Optimal selection is a function of the EMG amplitude and its derivatives. Simulation studies, in which EMG amplitude was changed randomly, found that the "best" adaptive filter performed as well as the "best" fixed-length filter. Experimental studies found the advantages of the adaptive processor to be situation dependent. Subjects used real-time EMG amplitude estimates to track a randomly-moving target. Perhaps due to task difficulty, no differences in adaptive versus fixed-length processors were observed when the target speed was fast. When the target speed was slow, the experimental results mere consistent with the simulation predictions. When the target moved between two constant levels, the adaptive processor responded rapidly to the target level transitions and had low variance while the target dwelled on a level.Keywords
This publication has 25 references indexed in Scilit:
- Probability density of the surface electromyogram and its relation to amplitude detectorsIEEE Transactions on Biomedical Engineering, 1999
- PC-based workstation for real-time acquisition, processing, and display of electromyogram signalsComputer Standards & Interfaces, 1999
- Optimal digital filtering requires a different cut-off frequency strategy for the determination of the higher derivativesJournal of Biomechanics, 1997
- Normality and stationarity of EMG signals of elbow flexor muscles during ramp and step isometric contractionsJournal of Electromyography and Kinesiology, 1997
- Multiple site electromyograph amplitude estimationIEEE Transactions on Biomedical Engineering, 1995
- A practical electrode-array myoprocessor for surface electromyographyIEEE Transactions on Biomedical Engineering, 1989
- Some Aspects of Nonstationary Myoelectric Signal ProcessingIEEE Transactions on Biomedical Engineering, 1987
- Analysis of a Digital EMG Signal Processor in Dynamic ConditionsIEEE Transactions on Biomedical Engineering, 1985
- A Note on the Time Constant in Low-Pass Filtering of Rectified Surface EMGIEEE Transactions on Biomedical Engineering, 1980
- An Optimality Criterion for Processing Electromyographic (EMG) Signals Relating to Human LocomotionIEEE Transactions on Biomedical Engineering, 1978