Dynamic Range and Mass Accuracy of Wide-Scan Direct Infusion Nanoelectrospray Fourier Transform Ion Cyclotron Resonance Mass Spectrometry-Based Metabolomics Increased by the Spectral Stitching Method
Open Access
- 19 May 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (12) , 4595-4602
- https://doi.org/10.1021/ac062446p
Abstract
Direct infusion nanoelectrospray Fourier transform ion cyclotron resonance mass spectrometry (DI nESI FT-ICR MS) offers high mass accuracy and resolution for analyzing complex metabolite mixtures. High dynamic range across a wide mass range, however, can only be achieved at the expense of mass accuracy, since the large numbers of ions entering the ICR detector induce adverse space-charge effects. Here we report an optimized strategy for wide-scan DI nESI FT-ICR MS that increases dynamic range but maintains high mass accuracy. It comprises the collection of multiple adjacent selected ion monitoring (SIM) windows that are stitched together using novel algorithms. The final SIM-stitching method, derived from several optimization experiments, comprises 21 adjoining SIM windows each of width m/z 30 (from m/z 70 to 500; adjacent windows overlap by m/z 10) with an automated gain control (AGC) target of 1 × 105 charges. SIM-stitching and wide-scan range (WSR; Thermo Electron) were compared using a defined standard to assess mass accuracy and a liver extract to assess peak count and dynamic range. SIM-stitching decreased the maximum mass error by 1.3- and 4.3-fold, and increased the peak count by 5.3- and 1.8-fold, versus WSR (AGC targets of 1 × 105 and 5 × 105, respectively). SIM-stitching achieved an rms mass error of 0.18 ppm and detected over 3000 peaks in liver extract. This novel approach increases metabolome coverage, has very high mass accuracy, and at 5.5 min/sample is conducive for high-throughput metabolomics.Keywords
This publication has 27 references indexed in Scilit:
- Multicomponent Internal Recalibration of an LC−FTICR-MS Analysis Employing a Partially Characterized Complex Peptide Mixture: Systematic and Random ErrorsAnalytical Chemistry, 2005
- How molecular profiling could revolutionize drug discoveryNature Reviews Drug Discovery, 2005
- Automated approach for quantitative analysis of complex peptide mixtures from tandem mass spectraNature Methods, 2004
- Accurate mass measurements by Fourier transform mass spectrometryMass Spectrometry Reviews, 2004
- Chemometric discrimination of unfractionated plant extracts analyzed by electrospray mass spectrometryPhytochemistry, 2003
- Nontargeted Metabolome Analysis by Use of Fourier Transform Ion Cyclotron Mass SpectrometryOMICS: A Journal of Integrative Biology, 2002
- Metabonomics: a platform for studying drug toxicity and gene functionNature Reviews Drug Discovery, 2002
- 'Metabonomics': understanding the metabolic responses of living systems to pathophysiological stimuli via multivariate statistical analysis of biological NMR spectroscopic dataXenobiotica, 1999
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Space charge effects in Fourier transform mass spectrometry. II. Mass calibrationAnalytical Chemistry, 1984