First‐pass evaluation of renal perfusion with turboflash MR imaging and superparamagnetic iron oxide particles
- 1 January 1993
- journal article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 3 (1) , 83-91
- https://doi.org/10.1002/jmri.1880030115
Abstract
First‐pass intrarenal hemodynamics were studied with superparamagnetic iron oxide particles and a T2‐weighted TurboFLASH (fast low‐angle shot) magnetic resonance (MR) imaging sequence. Four groups of five rabbits each were imaged after bolus injection of 40, 100, 140, and 200 μ,mol/kg iron, respectively. Images were acquired every 1.2 seconds, with an acquisition time of 700 msec. The signal intensity was measured in the cortex, outer medulla, inner medulla, and globally. In preliminary pathologic applications, two rabbits were imaged after ligation of the lumbar ureter and two after embolization of the renal artery. The reproducibil‐ity of the normal dynamics was evaluated with a cross‐correlation test. On the images, the intravas‐cular progression of the iron particles could be visualized within the cortex and the two compartments of the medulla in all cases. The maximal reduction in signal intensity in the cortex and medulla increased with the dose. The relationship between signal intensity decrease and dose was not linear, and the reproducibility of the signal intensity versus time plots was acceptable only at the 140 and 200 μ.mol/kg doses. The decrease in signal intensity was reduced and delayed in the emboli‐zed and hydronephrotic kidneys.Keywords
This publication has 21 references indexed in Scilit:
- Partial Residual Plots Based on Robust FitsTechnometrics, 2000
- Pharmacokinetics of Superparamagnetic Iron-Oxide MR Contrast Agents in the RatInvestigative Radiology, 1990
- Measurement of tissue blood flow using intravascular relaxation agents and resonance imagingMagnetic Resonance in Medicine, 1990
- Assessment of a superparamagnetic iron oxide (ami‐25) as a brain contrast agentMagnetic Resonance in Medicine, 1990
- A quantitative study of relaxation rate enhancement produced by iron oxide particles in polyacrylamide gels and tissueMagnetic Resonance in Medicine, 1989
- Cine-CT Measurement of Cortical Renal Blood FlowJournal of Computer Assisted Tomography, 1987
- Comparison of Initial Biodistribution Patterns of Gd-DTPA and Albumin-(Gd-DTPA) Using Rapid Spin Echo MR ImagingJournal of Computer Assisted Tomography, 1987
- Water Content and NMR Relaxation Time Gradients in the Rabbit KidneyInvestigative Radiology, 1986
- Xenon/CT Blood Flow Mapping of the Kidney and LiverJournal of Computer Assisted Tomography, 1984
- Intrarenal distribution of blood flow: Evolution of a new approach to measurementKidney International, 1984