Biventricular Assist Device Utilization for Patients with Morbid Congestive Heart Failure
- 30 August 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 112 (9_suppleme) , I65-72
- https://doi.org/10.1161/circulationaha.104.524934
Abstract
The rationale for the use of a biventricular assist device (BiVAD) for morbid congestive heart failure (MCHF) has been questioned because of historically unacceptable rates of postimplant and post-transplant mortality as well as perceived barriers to their outpatient management. All patients who received a Thoratec BiVAD from January 1990 to December 2003 at the University of Pittsburgh were studied retrospectively. There were a total of 73 patients (32% ischemic, 21% idiopathic, and 47% other) who had a BiVAD implanted. Before implantation, 100% were on > or =1 inotropic agent, and 77% had an intra-aortic balloon pump. Overall survival was 69%; 42 patients (84%) received cardiac transplantation, 5 patients (10%) were weaned, and 3 (6%) remained supported on BiVAD. If the 14 patients with postcardiotomy failure and acute myocardial infarction with shock are excluded, the overall survival improves to 75%. Five-year actuarial survival after heart transplantation was 58%. Of the 29 patients implanted before 2000, the 4-month actuarial freedom from driveline infections, bloodstream infections, and neurological events was 10%, 54%, and 48%, respectively, whereas the rates of these events for the 44 patients implanted after 2000 improved to 70%, 79%, and 80%, respectively. Since 2000, 21 (48%) patients were discharged from the hospital, of whom 38% went to an outpatient residence, 33% to a skilled nursing facility, and 29% to home. Once discharged, > or =1 readmission occurred in 45% and > or =2 readmissions in 48%. BiVAD support for MCHF has an acceptable overall mortality and survival to transplantation. Morbidity has been significantly reduced in the past 4 years, and management as an outpatient is achievable.Keywords
This publication has 20 references indexed in Scilit:
- Mechanical circulatory support device database of the international society for heart and lung transplantation: Second annual report—2004The Journal of Heart and Lung Transplantation, 2004
- The Registry of the International Society for Heart and Lung Transplantation: twenty-first official adult heart transplant report—2004The Journal of Heart and Lung Transplantation, 2004
- Role of the Abiomed BVS 5000 Device for Short-Term Support and Bridge to TransplantationAsaio Journal, 2004
- Coagulation monitoring and management of anticoagulation during cardiac assist device supportThe Annals of Thoracic Surgery, 2003
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureNew England Journal of Medicine, 2001
- Clinical impact of infections in left ventricular assist device recipients: The importance of site and organismTransplantation Proceedings, 1997
- Preoperative and postoperative comparison of patients with univentricular and biventricular support with the thoratec ventricular assist device as a bridge to cardiac transplantationThe Journal of Thoracic and Cardiovascular Surgery, 1997
- Transplant candidate's clinical status rather than right ventricular function defines need for univentricular versus biventricular supportThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Discharging patients who are undergoing mechanical circulatory supportThe Annals of Thoracic Surgery, 1996