Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner
- 1 December 1996
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 41 (12) , 2695-2704
- https://doi.org/10.1088/0031-9155/41/12/009
Abstract
A new method of dosimetry of ionizing radiations has been developed that makes use of tissue-equivalent polymer gels which are capable of recording three-dimensional dose distributions. The dosimetric data stored within the gels are measured using optical tomographic densitometry. The dose-response mechanism relies on the production of light scattering micro-particles which result from the polymerization of acrylic comonomers dispersed in the gel. The attenuation of a collimated light beam caused by scattering in the irradiated optically turbid medium is directly related to the radiation dose over the range 0 - 10 Gy. An optical scanner has been developed which incorporates an He - Ne laser, photodiode detectors, and a rotating gel platform. Using mirrors mounted on a translating stage, the laser beam scans across the gel between each incremental rotation of the platform. Using the set of optical density projections obtained, a cross sectional image of the radiation field is then reconstructed. Doses in the range 0 - 10 Gy can be measured to better than 5% accuracy with a spatial resolution of approximately 2 mm using the current prototype scanner. This method can be used for the determination of three-dimensional dose distributions in irradiated gels, including measurements of the complex distributions produced by multi-leaf collimators, dynamic wedge and stereotactic treatments, and for quality assurance procedures.Keywords
This publication has 7 references indexed in Scilit:
- Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gelPhysics in Medicine & Biology, 1996
- Radiation therapy dosimetry using magnetic resonance imaging of polymer gelsMedical Physics, 1996
- Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeterPhysics in Medicine & Biology, 1994
- Some sources of artefact in computed tomographyPhysics in Medicine & Biology, 1980
- Statistical limitations in computed tomographyPhysics in Medicine & Biology, 1978
- The Fourier reconstruction of a head sectionIEEE Transactions on Nuclear Science, 1974
- Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier TransformsProceedings of the National Academy of Sciences, 1971