X-ray exposure system using finely position adjusting apparatus
- 1 May 1978
- journal article
- Published by American Vacuum Society in Journal of Vacuum Science and Technology
- Vol. 15 (3) , 987-991
- https://doi.org/10.1116/1.569692
Abstract
An apparatus for finely adjusting the three‐dimensional position of a workpiece and the application of this apparatus to high power x‐ray lithography are presented. The relative positioning apparatus has been designed, using electrodynamic transducers for the x, y, and z directions and an electrostrictive transducer for rotary direction (ϑ). Motions in each direction are supported by a resilient plate. The relative position of mask and wafer has been detected by applying a mechanical vibration to the wafer, with an accuracy of less than ±0.1 μm. The fine positioning mechanisms have displayed excellent performance with high accuracies. As a first step to constructing a working apparatus, a prototype exposure system was built using pattern replication in an atmospheric environment, comprised of a positioning system and a high‐power x‐ray source with a rotary Al target operated at more than 20‐kW electron‐beam input power. The characteristic x ray has been irradiated on a wafer through a contractile vacuum pipe. Using an exposure test, the system functions have been confirmed as a fine pattern replicating system.Keywords
This publication has 0 references indexed in Scilit: