Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with nonthoracotomy lead systems.
- 1 August 1994
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 90 (2) , 868-872
- https://doi.org/10.1161/01.cir.90.2.868
Abstract
BACKGROUND: Traditional lead systems for implantable cardioverter defibrillators (ICDs) require a thoracotomy for placement. Nonthoracotomy lead systems are available and are usually implanted by an electrophysiologist and a surgeon. The purpose of this study was to prospectively evaluate the safety and efficacy of ICD implantation with a nonthoracotomy lead system by electrophysiologists. METHODS AND RESULTS: A consecutive series of 100 patients (mean age, 61 +/- 13 years, +/- SD) underwent ICD implantation with a nonthoracotomy lead system while intubated and under general anesthesia. Seventy-seven patients had coronary artery disease, 15 had idiopathic cardiomyopathy, 6 had miscellaneous heart disease, and 2 had structurally normal hearts. The mean ejection fraction was 0.29 +/- 0.13. Sixty-eight patients had suffered a cardiac arrest, and 32 had had ventricular tachycardia or syncope. All patients except 9 underwent electrophysiological testing and had failed 1 +/- 1 drug trials before ICD implantation. Three types of nonthoracotomy lead systems were used. The nonthoracotomy lead with an ICD was successfully implanted in 96 patients (96%). Of the unsuccessful implants, 1 patient did not have venous access, the passive fixation lead in 1 would not remain lodged, 1 had elevated defibrillation thresholds, and 1 developed a hemopneumothorax while venous access was being obtained. The mean defibrillation threshold was 17 +/- 6 J. The mean procedure duration was 161 +/- 57 minutes. When a subcutaneous patch was used (n = 58), the procedure duration was 189 +/- 5 minutes, and when a subcutaneous patch was not required (n = 40), the procedure lasted 123 +/- 37 minutes (P < .0001). Patients remained in the hospital 4.5 +/- 4.1 days after implantation, with no procedure-related deaths. Acute complications occurred in 10 patients; 2 had lead dislodgments, 1 with previous abdominal surgery had his abdominal cavity entered (without other complications) while the ICD pocket was being made, 1 had postoperative heart failure, 1 developed a large hematoma when anticoagulation therapy was initiated, 3 required reintubation because of excessive anesthesia, 1 developed superficial cellulitis, and 1 developed a hemopneumothorax secondary to a lacerated subclavian vein. During 6 +/- 3 months of follow-up, 2 patients developed lead fractures. CONCLUSIONS: (1) Electrophysiologists can implant an ICD with a nonthoracotomy lead system safely and with a high success rate; (2) use of a subcutaneous patch correlates with longer procedure durations; and (3) special precautions should be taken in patients with previous abdominal surgery.Keywords
This publication has 18 references indexed in Scilit:
- Determinats of successful nonthoracotomy cardioverter-defibrillator implantation: Experience in 101 patients using two different lead systemsJournal of the American College of Cardiology, 1993
- Clinical experience in seventy-seven patients with the automatic implantable cardioverter defibrillatorAmerican Heart Journal, 1989
- Intermittent Oversensing due to Internal Insulation Damage of Temperature Sensing Rate Responsive Pacemaker Lead in Subclavian Venipuncture MethodPacing and Clinical Electrophysiology, 1989
- Anatomical bases for a safe method of subclavian venipunctureSurgical and Radiologic Anatomy, 1989
- The automatic implantable cardioverter defibrillator: Efficacy, complications and survival in patients with malignant ventricular arrhythmiasJournal of the American College of Cardiology, 1988
- Antiarrhythmic drug efficacy for ventricular tachyarrhythmias associated with coronary artery disease as assessed by electrophysiologic studiesThe American Journal of Cardiology, 1985
- Determinants of Survival in Patients with Ventricular TachyarrhythmiasNew England Journal of Medicine, 1983
- Electrophysiologic testing in the management of survivors of out-of-hospital cardiac arrestThe American Journal of Cardiology, 1983
- Out-of-Hospital Cardiac ArrestNew England Journal of Medicine, 1980
- Surgical Endocardial Resection for the Treatment of Malignant Ventricular TachycardiaAnnals of Surgery, 1979