Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study
- 1 August 1997
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (8) , 1619-1632
- https://doi.org/10.1088/0031-9155/42/8/011
Abstract
Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an `ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during iterative reconstruction (`ideal scatter model', ISM); (iv) no scatter compensation (NSC); (v) ideal scatter rejection (ISR), as can be approximated by using a camera with a perfect energy resolution. The iterative method used was an ordered subset expectation maximization (OS-EM) algorithm. A cylinder containing small cold spheres was used to calculate contrast-to-noise curves. For a brain study, global errors between reconstruction and `true' distributions were calculated. Results show that ISR is superior to all other methods. In all cases considered, ISM is superior to ISE and performs approximately as well as (brain study) or better than (cylinder data) ISE-NF. Both ISM and ISE improve contrast-to-noise curves and reduce global errors, compared with NSC. In the case of ISE, blurring of the scatter estimate with a Gaussian kernel results in slightly reduced errors in brain studies, especially at low count levels. The optimal Gaussian kernel size is strongly dependent on the noise level.Keywords
This publication has 23 references indexed in Scilit:
- SPECT scatter modelling in non-uniform attenuating objectsPhysics in Medicine & Biology, 1997
- Bayesian reconstruction and use of anatomical a priori information for emission tomographyIEEE Transactions on Medical Imaging, 1996
- Block-iterative methods for image reconstruction from projectionsIEEE Transactions on Image Processing, 1996
- Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensationIEEE Transactions on Medical Imaging, 1996
- Multiwindow scatter correction techniques in single‐photon imagingMedical Physics, 1995
- Fast SPECT simulation including object shape dependent scatterIEEE Transactions on Medical Imaging, 1995
- Space-alternating generalized expectation-maximization algorithmIEEE Transactions on Signal Processing, 1994
- A new phantom for fast determination of the scatter response of a gamma cameraIEEE Transactions on Nuclear Science, 1994
- A fast projector-backprojector pair modeling the asymmetric, spatially varying scatter response function for scatter compensation in SPECT imagingIEEE Transactions on Nuclear Science, 1993
- Object shape dependent PSF model for SPECT imagingIEEE Transactions on Nuclear Science, 1993