Detection of High-Charge Density Polyanion Contaminants in Biomedical Heparin Preparations Using Potentiometric Polyanion Sensors
- 14 November 2008
- journal article
- other
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (24) , 9845-9847
- https://doi.org/10.1021/ac801879t
Abstract
A very simple and inexpensive method to detect oversulfated chondroitin sulfate (OSCS) or other high-charge density polyanionic structures as contaminants in heparin products using potentiometric polyanion sensors is described. In the potentiometric measurement, a greater change in the phase boundary equilibrium potential of polymeric membranes formulated with tridodecylmethylammonium (TDMA) anion exchange sites is observed for the contaminated heparin than for the untainted heparin due to the higher charge density of OSCS or other impurities compared to that of porcine heparin. Detection of 0.5 wt % OSCS impurity is readily achieved using only 1 mg/mL of final polyion concentration. Even lower detection limits for OSCS contamination may be possible if higher final concentrations of heparin preparations can be employed in the test procedure.Keywords
This publication has 13 references indexed in Scilit:
- Contaminated Heparin Associated with Adverse Clinical Events and Activation of the Contact SystemNew England Journal of Medicine, 2008
- Oversulfated chondroitin sulfate is a contaminant in heparin associated with adverse clinical eventsNature Biotechnology, 2008
- Implementing a best-treatment strategy with intracoronary brachytherapy for in-stent restenosis in patients at high risk for recurrenceCardiovascular Revascularization Medicine, 2007
- Essentials of anticoagulation in hemodialysisHemodialysis International, 2007
- Peer Reviewed: Polyion-Sensitive Membrane Electrodes for Biomedical AnalysisAnalytical Chemistry, 1996
- Extraction Thermodynamics of Polyanions into Plasticized Polymer Membranes Doped with Lipophilic Ion Exchangers: A Potentiometric StudyMacromolecules, 1995
- Response Mechanism of Polymer Membrane-Based Potentiometric Polyion SensorsAnalytical Chemistry, 1994
- “Fast moving” and “slow moving” heparins, dermatan sulfate, and chondroitin sulfate: qualitative and quantitative analysis by agarose-gel electrophoresisCarbohydrate Research, 1993
- Electrochemical sensor for heparin: further characterization and bioanalytical applicationsAnalytical Chemistry, 1993
- A colorimetric assay for chemical heparin in plasmaAnalytical Biochemistry, 1982