Submerged demineralize system processing of TMI-2 accident waste water
- 1 February 1983
- report
- Published by Office of Scientific and Technical Information (OSTI)
Abstract
Accident-generated radioactive waste at Three Mile Island Unit 2 includes a varity of high and low specific-activity waste. The high-specific-activity waste, particularly over one million gallons of contaminated water, required special processing and secondary waste handling. General public utilities and its contractors developed a zeolite-based ion-exchange system called the Submerged Demineralizer System to reduce contamination levels in the water to below allowable limits. Testing and modifications resulted in an operating system that had successfully processed waste water from the Reactor Coolant Bleed Tanks, the Reactor Building Basement, and the Reactor Coolant System as of August 1982. System design objectives were met and decontamination criteria established in 10 CFR 20 were attained. Additional wastes that could not be handled routinely were generated by another water-processing system, called EPICOR II. EPICOR II wastes are discussed. Low-specific-activity (LSA) wastes such as trash and resin-bed waste canisters are also included in handling. LSA wastes are routinely handled and shipped according to existing industry practice. Plant records are summarized to provide approximate yearly volumes and curie loadings of low-specific-activity wastes being shipped off the Island to a commercial burial site.Keywords
This publication has 0 references indexed in Scilit: