Inhalational drug delivery from seven different spacer devices.
Open Access
- 1 August 1996
- Vol. 51 (8) , 835-840
- https://doi.org/10.1136/thx.51.8.835
Abstract
BACKGROUND: A study was performed to determine in vitro the difference in drug output of seven currently available spacer devices when used with different inhaled medications. METHODS: A glass multistage liquid impinger (MSLI) was used to determine the amount of disodium cromoglycate (DSCG, 5 mg), salbutamol (100 micrograms), or budesonide (200 micrograms) obtained in various particle size ranges from metered dose inhalers (MDIs) actuated directly into the MSLI or via one of seven different spacer devices; the Fisonair, Nebuhaler, Volumatic, Inspirease, Aerochamber, Aerosol Cloud Enhancer, and Dynahaler. RESULTS: In particles smaller than 5 microns in diameter the dose of DSCG recovered from the Fisonair and Nebuhaler was 118% and 124%, respectively, of that recovered using the MDI alone. The dose recovered from the smaller volume spacers was 90% (Inspirease), 36% (Aerochamber), 33% (Aerosol Cloud Enhancer), and 21% (Dynahaler) of that from the MDI alone. The Volumatic increased the amount of salbutamol in particles smaller than 5 microns to 117% of that from the MDI, and the Inspirease and Aerochamber spacers decreased it by nearly 50%. The amount of budesonide in small particles recovered after use of the Nebuhaler, Inspirease, and the Aerochamber was 92%, 101%, and 78%, respectively, of that from the MDI alone. CONCLUSIONS: Under the test conditions used, large volume spacers such as the Fisonair, Nebuhaler, and Volumatic delivered significantly more DSCG and salbutamol than the smaller spacers tested. The differences between spacers were less for budesonide than the other medications studied. This study shows that there are significant differences in the amount of drug available for inhalation when different spacers are used as inhalational aids with different drugs. Spacer devices need to be fully evaluated for each drug prescribed for them.Keywords
This publication has 21 references indexed in Scilit:
- Optimum use of a spacer device.Archives of Disease in Childhood, 1993
- Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug.Thorax, 1993
- Drug delivery from holding chambers with attached facemask.Archives of Disease in Childhood, 1992
- Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler.Thorax, 1991
- Pressure flow characteristics of the valve in spacer devices.Archives of Disease in Childhood, 1989
- The growth of ambient aerosols in the conditions of the respiratory systemJournal of Aerosol Science, 1985
- Spacing devices and metered-dose inhalers in childhood asthmaThe Journal of Pediatrics, 1985
- Improvement of pressurised aerosol deposition with Nebuhaler spacer device.Thorax, 1984
- Comparison of three techniques of inhalation on the airway response to terbutaline.Thorax, 1983