Repeatability of measurements and sources of variability in tests of cardiovascular autonomic function
Open Access
- 1 August 1992
- Vol. 68 (8) , 205-211
- https://doi.org/10.1136/hrt.68.8.205
Abstract
Objective—To determine the repeatability and sources of variability of clinical tests of cardiovascular autonomic function. Design—The commonly used electrocardiographic related tests of autonomic function were studied. Two repeat measurements of all tests were made on all subjects on four separate days over a four week period. Subjects—Ten normal subjects with no known autonomic dysfunction were investigated. Main outcome measures—These were deep breathing (subject seated and supine), Valsalva manoeuvre, standing up from lying position, and normal relaxed breathing (subject supine). During the tests the electrocardiogram and respiratory pattern were recorded by computer. Beat to beat RR intervals were measured automatically from the electrocardiogram, and from these the results of the tests were calculated. Results—Variance analysis showed significant between subject variability for all tests (p < 0·005), but some tests showed a much smaller relative within subject variability than others. Average repeatability data (within subject SD) for each test were calculated, and included deep breathing sitting (maxmin) RR (46 ms), Valsalva ratio (0·17), and lying to standing RR ratio (0·11). These compare with between subject SDs of 65 ms, 0·38, and 0·13 respectively, at mean values of 305 ms, 1·92, and 1·15 respectively. The data highlighted one subject with the poorest repeatability, whose electrocardiogram turned out on closer inspection to be under atrial rather than sinus control at times. Poor repeatability in the other subjects was related to variability in the respiratory pattern, and in the deep breathing test, repeat variability was significantly correlated (r = 0·79) with variability in the respiratory amplitude (p < 0·05). Conclusions—Repeatability data should be available to each laboratory carrying out autonomic function tests. The data provided in this study could be used as a baseline. Poor repeatability highlights the need to re-examine the test procedures, or the test data from specific subjects. Variability of respiratory pattern is associated with poor repeatability, and so careful instructions on respiration should be given to each subject before the tests.Keywords
This publication has 23 references indexed in Scilit:
- Testing of autonomic cardiovascular regulation—methodological considerationsClinical Physiology and Functional Imaging, 1989
- AGE-ADJUSTED NORMAL TOLERANCE LIMITS FOR CARDLOVASCULAR AUTONOMIC FUNCTION ASSESSMENT IN THE ELDERLYAge and Ageing, 1986
- Heart rate variability in healthy subjects: effect of age and the derivation of normal ranges for tests of autonomic function.Heart, 1986
- The Value of Cardiovascular Autonomic Function Tests: 10 Years Experience in DiabetesDiabetes Care, 1985
- Measurement of chest wall movement; design, performance and clinical use of a four-channel magnetometer instrumentClinical Physics and Physiological Measurement, 1983
- Reduced sinus arrhythmia in diabetic autonomic neuropathy: diagnostic value of an age-related normal range.BMJ, 1982
- Diagnosis and management of diabetic autonomic neuropathy.BMJ, 1982
- Respiratory influence on heart rate in diabetes mellitus.BMJ, 1979
- A simple test of cardiac function based upon the heart rate changes induced by the valsalva maneuverThe American Journal of Cardiology, 1966
- ABSENT CIRCULATORY REFLEXES IN DIABETIC NEURITISThe Lancet, 1960