Detection of Chlamydia trachomatis by the polymerase chain reaction in swabs and urine from men with non-gonococcal urethritis.
Open Access
- 1 April 1991
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 44 (4) , 321-325
- https://doi.org/10.1136/jcp.44.4.321
Abstract
A polymerase chain reaction (PCR) was developed for Chlamydia trachomatis in which a 380 base pair DNA fragment was amplified. Amplification occurred with the DNA from the 15 serovars but not with that from other Chlamydia spp or with DNA from a variety of other organisms. Chlamydial DNA (10(-16) g) could be detected and the PCR seemed to be able to detect single organisms. Urethral swabs were obtained from 37 men with acute non-gonococcal urethritis (NGU), 18 (49%) of whom were positive for C trachomatis by MicroTrak. As a result of clinical re-examinations 65 urethral swabs were available for analysis by the PCR. In comparison with MicroTrak, PCR had a sensitivity of 95%, a specificity of 94%, a positive predictive value of 86% and a negative predictive value of 98%. The PCR was apparently less sensitive (82%) in tests on urine samples. Overall, however, values of sensitivity and specificity of the PCR compared favourably with those of MicroTrak. The PCR for C trachomatis is likely to be a valuable technique for research, but problems of DNA contamination suggest that it should not be recommended for routine diagnosis.Keywords
This publication has 38 references indexed in Scilit:
- Development and evaluation of the polymerase chain reaction to detect Mycoplasma genitaliumFEMS Microbiology Letters, 1991
- Current problems in microbiology: 1. Chlamydial infections: which laboratory test?Journal of Clinical Pathology, 1991
- Use of the polymerase chain reaction to detect DNA sequences specific to pathogenic treponemes in cerebrospinal fluidFEMS Microbiology Letters, 1990
- A polymerase chain reaction (PCR) protocol for the specific detection of Chlamydia sppMolecular and Cellular Probes, 1989
- Avoiding false positives with PCRNature, 1989
- Improved sensitivity of a modified polymerase chain reaction amplified DNA probe in comparison with serial tissue culture passage for detection of Chlamydia trachomatis in conjunctival specimens from nepalDiagnostic Microbiology and Infectious Disease, 1989
- What Price Success? The Continuing Saga of the Toxic: Therapeutic Ratio in the Use of Aminoglycoside AntibioticsThe Journal of Infectious Diseases, 1988
- Use of nucleic acid probes for the detection of sexually transmitted infectious agentsDiagnostic Microbiology and Infectious Disease, 1986
- Detection of Chlamydia trachomatis in Clinical Specimens by Nucleic AcidMicrobiology, 1985
- Sensitivity of detecting Chlamydia trachomatis elementary bodies in smears by use of a fluorescein labelled monoclonal antibody: comparison with conventional chlamydial isolation.Journal of Clinical Pathology, 1984