PMMA particles and pressure—a study of the osteolytic properties of two agents proposed to cause prosthetic loosening
Open Access
- 1 March 2003
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 21 (2) , 196-201
- https://doi.org/10.1016/s0736-0266(02)00150-x
Abstract
Amongst the wear debris particles implicated in the particle hypothesis for prosthetic loosening are polymethylmethacrylate (PMMA), and particularly PMMA with barium sulphate contrast agent. Another suggested cause for loosening is hydrostatic pressure. PMMA particles were combined with hydrostatic pressure in a study to investigate whether there could be a synergistic or additive effect between these two factors. Titanium plates were fastened onto tibiae of 59 rats. After osseointegration, PMMA particles with barium sulphate were administered to the bone‐implant interface. Further, PMMA particles were introduced into a previously published model for hydrostatic pressure induced osteolysis. There was measurable resorption in response to the PMMA particles but no additive or synergistic effect from introducing particles to the pressure model, and the effect of pressure was far greater than that of particles. These results suggest that, whereas particles can be shown to elicit an osteolytic response, the much less studied osteolytic effects of pressure could be far more important. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.Keywords
This publication has 27 references indexed in Scilit:
- Effect of polymethylmethacrylate particles on mature bone in the optical bone chamberJournal of Biomedical Materials Research, 2001
- Production of TNF-α and bone resorbing activity by macrophages in response to different types of bone cement particlesBiomaterials, 2000
- Tumor Necrosis Factor-α Mediates Orthopedic Implant OsteolysisThe American Journal of Pathology, 1999
- In Vitro, In Vivo, and Tissue Retrieval Studies on Particulate DebrisClinical Orthopaedics and Related Research, 1998
- THE EFFECTS OF PARTICULATE POLYETHYLENE AT A WEIGHT-BEARING BONE-IMPLANT INTERFACEThe Journal of Bone and Joint Surgery. British volume, 1996
- Mechanical influences on tissue differentiation at bone—cement interfacesThe Journal of Arthroplasty, 1995
- Theories of wear and loosening in hip prostheses: Wear-induced loosening vs loosening-induced wear–a reviewActa Orthopaedica, 1994
- Osteolysis and particle disease in hip replacement: A reviewActa Orthopaedica, 1994
- Arthrography after total hip arthroplasty: a modified technique used in the diagnosis of pain.Radiology, 1983
- Determination of lipid A and endotoxin in serum by mass spectroscopyProceedings of the National Academy of Sciences, 1978