Model calculations for ultrasonic plate - liquid - plate resonators: peak frequency shift by liquid density and velocity variations
- 1 June 1997
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 8 (6) , 643-647
- https://doi.org/10.1088/0957-0233/8/6/010
Abstract
Ultrasonic resonators - consisting of the liquid sample, enclosed by two planar piezoelectric transducer plates - permit a direct and accurate determination of liquid sound velocities at kilohertz and megahertz frequencies. Such plate - liquid - plate (PLP) resonators offer a resolution , which is important for analytical work in chemistry, bio- and physico-chemistry and for some technical applications. A simple one-dimensional resonator model is derived which permits calculation of the spectrum of the longitudinal (nonharmonic) eigenfrequencies (n = 1, 2, 3, 4 ...) as a function of liquid and resonator parameters. This model obtains the peak shift by variation of liquid velocity and density as well for plane wave propagation; the effect from variations in has been neglected in most ultrasonic studies so far. Caused by a frequency-dependent phase shift for sound reflection at both liquid/transducer interfaces, the differential quotients and of the `real' resonator deviate from those of an `ideal' PLP resonator with perfect, `hard' reflection (reflection factor ) and harmonic overtones ( is the liquid fundamental frequeny; one half liquid wavelength equals transducer separation x). The figures show typical acoustic impedance and admittance spectra, which are calculated for a model configuration; they illustrate features of the harmonic numbers in the liquid cavity and longitudinal mode counting. Equations are given for the dimensionless, normalized differential quotients and . Plots demonstrate systematic aberrations from `ideal' resonator behaviour, which can affect high-precision sound velocity measurements.Keywords
This publication has 9 references indexed in Scilit:
- Broad-band ultrasonic measurement techniques for liquidsMeasurement Science and Technology, 1996
- New plano-concave ultrasonic resonator cells for absorption and velocity measurements in liquids below 1 MHzMeasurement Science and Technology, 1994
- Theoretical analysis of an ultrasonic interferometer for precise measurements at high pressuresUltrasonics, 1991
- Ultrasonic Velocimetry Of Biological CompoundsAnnual Review of Biophysics, 1991
- Acoustical absorption spectroscopy of liquids between 0.15 and 3000 MHz. I. High resolution ultrasonic resonator methodJournal of Physics E: Scientific Instruments, 1987
- Development of methods of precise ultrasonic measurements in small volumes of liquidsUltrasonics, 1982
- A High Resolution and Low Volume Ultrasonic Resonator Method for Fast Chemical Relaxation MeasurementsBerichte der Bunsengesellschaft für physikalische Chemie, 1976
- Ultrasonic Measurements with Milliliter Liquid Samples in the 0.5–100 MHz RangeReview of Scientific Instruments, 1973
- Shift in the Location of Resonant Frequencies Caused by Large Electromechanical Coupling in Thickness-Mode ResonatorsThe Journal of the Acoustical Society of America, 1963