An intrinsic positive end-expiratory pressure lung model, with and without flow limitation
- 1 July 1996
- journal article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 24 (7) , 1261-1265
- https://doi.org/10.1097/00003246-199607000-00033
Abstract
To design an intrinsic positive end-expiratory pressure (PEEP) lung model that has the property of air flow limitation. Mechanical lung model study of intrinsic PEEP. Lung models were set up in the research laboratory. Intrinsic PEEP lung models were created with and without flow limitation. In the model with flow limitation, intrinsic PEEP was created by replacing a portion of the expiratory circuit with a collapsible Penrose tube and by placing this portion the circuit under water. The expiratory circuit became a part of the respiratory airway, with flow limitation occurring at the Penrose drain. In the model without flow limitation, intrinsic PEEP was generated with a fixed linear resistor, which was inserted in the expiratory circuit to produce a similar level of intrinsic PEEP. Multiple levels of external PEEP, both above and below the initial intrinsic PEEP, were applied. At each level of external PEEP, peak airway pressure, plateau airway pressure, isovolume air flow, internal lung pressure, and intrinsic PEEP were measured. Peak airway pressure, plateau pressure, and internal lung pressure were minimally affected if the external PEEP was less than the intrinsic PEEP in the lung model with flow limitation. Intrinsic PEEP was reduced with external PEEP. However, if intrinsic PEEP was induced without dynamic airway closure or flow limitation, any level of external PEEP caused an immediate increase in peak airway pressure, plateau airway pressure, and internal lung pressure and a decrease in isovolume flow. External PEEP has little effect on the levels of intrinsic PEEP. We demonstrated two different models of an intrinsic PEEP lung model. The interactions between intrinsic PEEP and externally applied PEEP were different. The lung model with collapsible tube closely simulated the human respiratory system with flow limitation. This lung model may be useful for the future study of intrinsic PEEP and pulmonary mechanics.Keywords
This publication has 14 references indexed in Scilit:
- Variability of intrinsic positive end-expiratory pressure in patients receiving mechanical ventilationCritical Care Medicine, 1995
- Comparison of static and dynamic measurements of intrinsic PEEP in mechanically ventilated patients.American Journal of Respiratory and Critical Care Medicine, 1994
- Interaction between intrinsic positive end-expiratory pressure and externally applied positive end-expiratory pressure during controlled mechanical ventilationCritical Care Medicine, 1993
- A simple method for the measurement of intrinsic positive end-expiratory pressure during controlled and assisted modes of mechanical ventilationCritical Care Medicine, 1992
- Strategies to Minimize Breathing Effort During Mechanical VentilationCritical Care Clinics, 1990
- The Role of Airflow Resistance in Patients with the Adult Respiratory Distress SyndromeAmerican Review of Respiratory Disease, 1989
- Evidence for Chronic Inflammation as a Component of the Interstitial Lung Disease Associated with Progressive Systemic SclerosisAmerican Review of Respiratory Disease, 1985
- Effect of antimony ion implantation on Al-silicon Schottky diode characteristicsJournal of Applied Physics, 1984
- Influence of Positive End-Expiratory Pressure on Left Ventricular PerformanceNew England Journal of Medicine, 1981
- Influence of state of inflation of the lung on pulmonary vascular resistanceJournal of Applied Physiology, 1960