Dorsal-Enhanced Sutures Improve Tension Resistance of Tendon Repair
- 1 April 2002
- journal article
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 27 (2) , 161-164
- https://doi.org/10.1054/jhsb.2001.0687
Abstract
Thirty-six fresh pig flexor tendons were repaired using either the modified Kessler method or the Tang method. Nine tendons from each group were tested in an Instron tensile testing machine with the tendons passing 90° around a pulley. The other nine tendons from each group were pulled linearly by the testing machine. The 2mm gap formation force of the tendons repaired with the modified Kessler and Tang methods and pulled at 90° were 64%±5% and 79%±9% respectively of those forces recorded during linear testing. The ultimate strengths of tendons repaired by the modified Kessler and Tang methods and pulled at 90° were 76%±6% and 81%±8% respectively of the forces measured during linear testing. The percentage gap formation and ultimate strength of the Tang method was significantly higher than that of the modified Kessler suture when the tendons were pulled around a pulley. This demonstrates that the Tang suture, with its main components in the dorsal part of the repaired tendon, has greater tension resistance capacity than conventional tendon sutures which are placed in the middle of the tendon. This study suggests that dorsally-enhanced multiple tendon sutures are better placed to sustain the tension generated during active finger flexion.Keywords
This publication has 23 references indexed in Scilit:
- A randomized biomechanical study of zone II human flexor tendon repairs analyzed in an in vitro modelThe Journal of Hand Surgery, 1998
- Mechanical Strengths of Tendon SuturesJournal of Hand Surgery (European Volume), 1998
- The effects of multiple-strand suture methods on the strength and excusion of repaired intrasynovial flexor tendons: A biomechanical study in dogsThe Journal of Hand Surgery, 1998
- Tensile strength of flexor tendon repairs in a bynamic cadaver modelThe Journal of Hand Surgery, 1996
- The Double Sheath System and Tendon Gliding in Zone 2CJournal of Hand Surgery (European Volume), 1995
- Augmented becker versus modified kessler tenorrhaphy in monkeys: Dynamic mechanical analysisThe Journal of Hand Surgery, 1995
- Double and Multiple Looped Suture Tendon RepairJournal of Hand Surgery (European Volume), 1994
- The Rupture Rate of Acute Flexor Tendon Repairs Mobilized by the Controlled Active Motion RegimenPublished by SAGE Publications ,1994
- Flexor Tendon Repair in Zone 2CJournal of Hand Surgery (European Volume), 1994
- Intra-tendinous tendon suture in the hand A new techniqueThe Hand, 1975