A common source outbreak of Acinetobacter pulmonary infections traced to Wright respirometers
Open Access
- 1 March 1980
- journal article
- research article
- Published by Oxford University Press (OUP) in Postgraduate Medical Journal
- Vol. 56 (653) , 169-172
- https://doi.org/10.1136/pgmj.56.653.169
Abstract
Over a 30-day period, Acinetobacter calcoaceticus var. antiratus was the responsible pathogen for hospital-acquired pneumonia in 10 patients, and resulted in the colonization of the upper respiratory tract in an additional 9 patients. Wright respirometers contaminated by this organism were shown to be the common source for the outbreak as indicated by the recovery of a single serotype (8J), the inability to recover Acinetobacter from any other environmental source, and the demonstration that moisturized Wright respirometers are capable of "aerosolizing" fluids containing Acinetobacter.This publication has 12 references indexed in Scilit:
- Acinetobacter calcoaceticus variety anitratusThe Lancet Healthy Longevity, 1979
- Airborne Contamination of Fine-Particle NebulizersJAMA, 1977
- INFECTIONS WITH ACINETOBACTER CALCOACETICUS (HERELLEA VAGINICOLA)Medicine, 1977
- Activity of Minocycline Against Acinetobacter calcoaceticus Var. anitratus (Syn. Herellea vaginicola ) and Serratia MarcescensAntimicrobial Agents and Chemotherapy, 1975
- Nonfermentative gram-negative bacilli of nosocomial interestThe American Journal of Medicine, 1970
- The Bacteria Mima-Herellea: Isolation and Clinical Significance in a General HospitalAmerican Journal of Clinical Pathology, 1967
- Organisms of the Tribe MimeaeSouthern Medical Journal, 1965
- Evaluation of the Clinical Significance of the Genus HerelleaAnnals of Internal Medicine, 1964
- Lobar pneumonia with bacteremia caused by bacterium anitratumThe American Journal of Medicine, 1959