Standardized Abnormal Interpretation and Cancer Detection Ratios to Assess Reading Volume and Reader Performance in a Breast Screening Program
- 1 May 2000
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 215 (2) , 563-567
- https://doi.org/10.1148/radiology.215.2.r00ma42563
Abstract
To determine the relationship between annual screening volume and radiologist performance in the Screening Mammography Program of British Columbia, Canada. Standardized abnormal interpretation ratios and standardized cancer detection ratios were constructed for 35 readers with at least 3 years of experience with the Screening Mammography Program of British Columbia. The ratios were used to compare individual reader performance with the mean program performance after adjustment for the age and screening history (first versus subsequent screening examinations) of the women who underwent screening. The mean standardized abnormal interpretation ratio was better for readers of 2,000-2,999 (n = 8) and 3,000-3,999 (n = 9) screening mammograms per year than for those of less than 2,000 (n = 9) and 4, 000-5,199 (n = 9) screening mammograms per year. Differences in the mean standardized abnormal interpretation ratios were significant (P <.05) between the readers of less than 2,000 and of 2,000-2,999 screening mammograms per year, between readers of less than 2,000 and of 3,000-3,999 screening mammograms per year and between readers of 3,000-3,999 and of 4,000-5,199 screening mammograms per year. The mean standardized cancer detection ratio improved gradually with increasing annual volume, but the differences between groups were not statistically significant. Five of the eight readers of 2,000-2, 999 mammograms were reading 2,475 or more screening mammograms per year. Standardized abnormal interpretation ratios and standardized cancer detection ratios provide a method of comparing two important performance measures in a screening program. A minimum of 2,500 interpretations per year is associated with lower abnormal interpretation rates and average or better cancer detection rates.Keywords
This publication has 11 references indexed in Scilit:
- Results from the Ontario breast screening program, 1990–1995Journal of Medical Screening, 1998
- Nation-wide breast cancer screening in The Netherlands: Results of initial and subsequent screening 1990–1995International Journal of Cancer, 1998
- Monitoring the Performance of Breast Screening Programmes: Use of Indirect Standardisation in Evaluating the Invasive Cancer Detection RateJournal of Medical Screening, 1996
- Long term breast cancer screening in Nijmegen, The Netherlands: the nine rounds from 1975-92.Journal of Epidemiology and Community Health, 1996
- Quality-oriented mass mammography screening.Radiology, 1995
- Assessment of Lesions Detected at Mammographic Screening: Performance at First or Repeat Screening in the Florence ProgrammeJournal of Medical Screening, 1994
- Screening mammography in British Columbia: 1988–1993The American Journal of Surgery, 1994
- Quality assurance and cancer detection rates in a provincial screening mammography program. Work in progress.Radiology, 1993
- The British Columbia Mammography Screening Program: evaluation of the first 15 months.American Journal of Roentgenology, 1992
- Medical audit of a rapid-throughput mammography screening practice: methodology and results of 27,114 examinations.Radiology, 1990