Measuring Knee Extensor Muscle Strength
- 1 January 2001
- journal article
- research article
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 80 (1) , 13-18
- https://doi.org/10.1097/00002060-200101000-00004
Abstract
To compare manual muscle test with hand-held dynamometer measurements of knee extension strength. A secondary analysis of measurements (n = 256 knees) from 128 acute rehabilitation patients was performed. Knee extensor muscle testing was conducted according to the technique of Hislop and Montgomery; 0 to 5 grades were converted to an expanded 0 to 12 scale. Dynamometry was used to measure the isometric knee extension force with ‘gravity eliminated.‘ Manual muscle test and dynamometer measures were highly correlated (r = 0.768;P < 0.001); the correlation was higher when the quadratic nature of the relationship was taken into account (R = 0.887;P < 0.001). Although the dynamometer forces that were associated with different manual muscle test grades differed overall (F = 67.736;P < 0.001), the forces associated with some of the higher grades did not differ statistically. These findings reinforce the convergent construct validity of the manual muscle test and dynamometry measurements but challenge the discriminant construct validity of manual muscle testing. An alternative manual muscle testing grading scheme is suggested that provides for discriminant validity and retains convergent validity.Keywords
This publication has 13 references indexed in Scilit:
- Alternatives for measuring knee extension strength of the elderly at homeClinical Rehabilitation, 1998
- Hand-grip dynamometry provides a valid indication of upper extremity strength impairment in home care patientsJournal of Hand Therapy, 1998
- Comparison of three methods to assess muscular strength in individuals with spinal cord injurySpinal Cord, 1998
- A Comparative Study of Isokinetic Dynamometry and Manual Muscle Testing of Ankle Dorsal and Plantar Flexors and Knee Extensors and FlexorsEuropean Neurology, 1997
- Wrist Strength Measured by Myometry as an Indicator of Functional IndependenceJournal of Neurotrauma, 1995
- Comparative Assessment of Knee Strength Using Hand-Held Myometry and Isometric Dynamometry in Patients with Inflammatory MyopathyPhysiotherapy Theory and Practice, 1995
- Reliability of Hand-Held Dynamometry and Its Relationship with Manual Muscle Testing in Patients with Osteoarthritis in the KneeJournal of Orthopaedic & Sports Physical Therapy, 1992
- Relationship of manual muscle testing to objective strength measurementsMuscle & Nerve, 1989
- Influence of Method on Estimates of Normal Knee Extensor Force among Normal and Postpolio Children*PTJ: Physical Therapy & Rehabilitation Journal, 1956
- CERTAIN ASPECTS OF INFANTILE PARALYSISJAMA, 1916