Comparison of Percent Total GHb With Percent HbA1c in People With and Without Known Diabetes
- 1 September 1998
- journal article
- research article
- Published by American Diabetes Association in Diabetes Care
- Vol. 21 (9) , 1475-1480
- https://doi.org/10.2337/diacare.21.9.1475
Abstract
OBJECTIVE To directly compare results obtained using an ion-exchange high-performance liquid chromatography (HPLC) HbA1c method used in the Diabetes Control and Complications Trial with two different affinity chromatography methods in which ”total GHb” is determined. RESEARCH DESIGN AND METHODS Blood was obtained from a large number of people with and without known diabetes. The specimens were divided and assayed for HbA1c and for total GHb. Total GHb was determined using a semi-automated gravity-elution boronate affinity chromatography method and an automated boronate affinity HPLC method. The results obtained with the two methods were also compared. RESULTS In subjects without known diabetes, the mean percentage HbA1c and the range of values were similar to the total GHb values in the same subjects when assayed using the semi-automated affinity gravity-elution method (mean 5.2 ± 0.4 and 5.1 ± 0.4% [SD], respectively). With the affinity HPLC method, results were 5.3 ± 0.4%. The similarity in results was surprising. However, analysis of the data suggests that a large proportion of the material in the HbA1c fraction measured using this ion-exchange HPLC method is not GHb, as pointed out by others. Although the results were similar in people without known diabetes, in the people with diabetes, the incremental increase was ∼25% greater for the total GHb when compared with the increase in HbA1c. When corrected for the non-GHb being measured by the HbA1c method, it can be calculated that ∼40% more GHb is measured using affinity chromatography over the entire range of GHb values. CONCLUSIONS The similarity in the mean and range of percent HbA1c and in percent total GHb using these different methods can be attributed to two factors: 1) the HbA1c ion-exchange method measures only ∼ 50–60% of the total GHb present, and 2) ∼ 40–50% of the material being measured in the HbA1c fraction is not GHb, i.e., offsetting factors fortuitously resulted in values similar to the more specific affinity methods. The greater incremental increase in percent total GHb compared with percent HbA1c in people with diabetes can be attributed to the greater amount of GHb being measured with the affinity methods.This publication has 11 references indexed in Scilit:
- Evaluation of GHb Assays in France by National Quality Control SurveysDiabetes Care, 1998
- Another Step Toward Standardization of Methods for Measuring Hemoglobin A1cClinical Chemistry, 1997
- Potential of electrospray mass spectrometry for quantifying glycohemoglobinClinical Chemistry, 1997
- Glycemic control: perhaps we can define it, but can we measure it?Clinical Chemistry, 1995
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- Determination of glycated hemoglobin by affinity chromatographyClinica Chimica Acta; International Journal of Clinical Chemistry, 1987
- The Clinical Information Value of the Glycosylated Hemoglobin AssayNew England Journal of Medicine, 1984
- APPLICATION OF AFFINITY-CHROMATOGRAPHY FOR SEPARATION AND QUANTITATION OF GLYCOSYLATED HEMOGLOBINS1983
- Determination of glycosylated hemoglobin by affinity chromatography: comparison with colorimetric and ion-exchange methods, and effects of common interferences.Clinical Chemistry, 1982
- Sites of nonenzymatic glycosylation of human hemoglobin A.Journal of Biological Chemistry, 1980