Determination of the optimal ammonium sulfate concentration for the fractionation of rabbit, sheep, horse, and goat antisera.
- 1 January 1973
- journal article
- Vol. 25 (1) , 26-36
Abstract
Various ammonium sulfate concentrations and reaction conditions were employed in the fractionation of sera from rabbits, sheep, horses, and goats. Precipitates and supernatant fluids were analyzed by electrophoresis to study the effects of the controlled variables. At room temperature, the third precipitate in 35% saturated (NH(4))(2)SO(4) was the best fraction from both rabbit and sheep sera; 80 to 90% of the gamma globulins were recovered. The second and third precipitates of horse sera proteins in 30% saturated (NH(4))(2)SO(4) were both satisfactory, but only 44% of the gamma globulin was recovered after three precipitations. Goat sera yielded a very satisfactory fraction; 80% of the gamma globulin was recovered after two precipitations-the first in 30% and the second in 45% saturated (NH(4))(2)SO(4). The composition of these fractions was not influenced by the pH of the sulfate solutions (pH 5.8 and 7.2), by a range of normal room temperatures (20 to 30 C), or by diluting the sera before fractionation. Crude globulins and fluorescein isothiocyanate-labeled globulins were successfully refractionated by one precipitation in the optimal sulfate concentration for the appropriate animal species. The refractionated products contained considerably less beta and alpha globulins than did the original crude fractions and little or no albumin.This publication has 7 references indexed in Scilit:
- Preparation and testing of polyvalent conjugates for fluorescent-antibody detection of salmonellae.1971
- THE DEFINITION AND APPLICATION OF EVALUATION TECHNIQUES AS A GUIDE FOR THE IMPROVEMENT OF FLUORESCENT ANTIBODY REAGENTSAnnals of the New York Academy of Sciences, 1971
- Factors Affecting the Degree of Nonspecific Staining Given by Fluorescein Isothiocyanate Labeled GlobulinsThe Journal of Immunology, 1967
- FACTORS AFFECTING REMOVAL OF (NH4)2SO4 FROM SALT FRACTIONATED SERUM GLOBULINS EMPLOYING A SPECTROPHOTMETRIC PROCEDURE FOR DETERMINATION OF SULFATE.1965
- Fluorescein diacetate as a reference color standard in fluorescent antibody studiesAnalytical Biochemistry, 1964
- Factors Affecting the Rate of Reaction of Fluorescein Isothiocyanate with Serum ProteinsThe Journal of Immunology, 1964
- Technical Factors Affecting the Preparation of Fluorescent Antibody ReagentsThe Journal of Immunology, 1961