Detection of necrosis in human tumour xenografts by proton magnetic resonance imaging
Open Access
- 1 March 1995
- journal article
- Published by Springer Nature in British Journal of Cancer
- Vol. 71 (3) , 456-461
- https://doi.org/10.1038/bjc.1995.93
Abstract
Tumours with necrotic regions have an inadequate blood supply and are expected to differ from well-vascularised tumours in response to treatment. The purpose of the present work was to investigate whether proton magnetic resonance imaging (MRI) might be used to detect necrotic regions in tumours. MR images and histological sections from individual tumours of three different amelanotic human melanoma xenograft lines (BEX-t, HUX-t, SAX-t) were analysed in pairs. MRI was performed at 1.5 T using two spin-echo pulse sequences, one with a repetition time (TR) of 600 ms and echo times (TEs) of 20, 40, 60 and 80 ms and the other with a TR of 2000 ms and TEs of 20, 40, 60 and 80 ms. Spin-lattice relaxation time (T1), spin-spin relaxation time (T2) and proton density (N0) were calculated for each volume element corresponding to a pixel. Synthetic MR images, pure T1, T2 and N0 images and spin-echo images with chosen values for TR and TE were generated from these data. T1, T2 and N0 distributions of tumour subregions, corresponding to necrotic regions and regions of viable tissue as defined by histological criteria, were also generated. T1 and T2 were significantly shorter in the necrotic regions than in the regions of viable tissue in all tumours. These differences were sufficiently large to allow the generation of synthetic spin-echo images showing clear contrast between necrosis and viable tissue. Maximum contrast was achieved with TRs within the range 2800-4000 ms and TEs within the range 160-200 ms. Necrotic tissue could also be distinguished from viable tissue in pure T1 and T2 images. Consequently, the possibility exists that MRI might be used for detection of necrotic regions in tumours and hence for prediction of tumour treatment response.Keywords
This publication has 19 references indexed in Scilit:
- Establishment and characterization of six human melanoma xenograft linesAPMIS, 1990
- Identification of tumor hemorrhage in an animal model using spin echoes and gradient echoesMagnetic Resonance in Medicine, 1990
- Blood flow, oxygen and nutrient supply, and metabolic microenvironment of human tumors: a review.1989
- In vivo magnetic resonance imaging of the effects of photodynamic therapyBritish Journal of Cancer, 1989
- PET in clinical oncologyCancer and Metastasis Reviews, 1988
- Tumor BiologyAmerican Journal of Clinical Oncology, 1988
- Determinants of tumor blood flow: a review.1988
- 1H-NMR relaxation times and water compartmentalization in experimental tumor modelsMagnetic Resonance Imaging, 1986
- Proton spin-lattice relaxation studies of tissue response to radiotherapy in micePhysics in Medicine & Biology, 1983
- The Histological Structure of Some Human Lung Cancers and the Possible Implications for RadiotherapyBritish Journal of Cancer, 1955