Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET
- 6 July 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (14) , 3313-3322
- https://doi.org/10.1088/0031-9155/50/14/008
Abstract
High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.Keywords
This publication has 20 references indexed in Scilit:
- Predictive Cardiac Motion Modeling and Correction With Partial Least Squares RegressionIEEE Transactions on Medical Imaging, 2004
- The design and implementation of a motion correction scheme for neurological PETPhysics in Medicine & Biology, 2003
- A study of the motion and deformation of the heart due to respirationIEEE Transactions on Medical Imaging, 2002
- PET-CT image co-registration in the thorax: influence of respirationEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Three-dimensional contour detection of left ventricular myocardium using elastic surfacesEuropean Journal of Nuclear Medicine and Molecular Imaging, 1999
- Cardiac and respiratory gating of list-mode data on a high sensitivity PET scanner, the ECAT EXACT3DJournal of Nuclear Cardiology, 1999
- Real-time system for respiratory-cardiac gating in positron tomographyIEEE Transactions on Nuclear Science, 1998
- Experience with fully 3D PET and implications for future high-resolution 3D tomographsPhysics in Medicine & Biology, 1998
- Respiratory kinematics of the upper abdominal organs: A quantitative studyMagnetic Resonance in Medicine, 1992
- Electrocardiographic Gating in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979