Validation of Short Tandem Repeats (STRs) for Forensic Usage: Performance Testing of Fluorescent Multiplex STR Systems and Analysis of Authentic and Simulated Forensic Samples
- 1 May 2001
- journal article
- research article
- Published by ASTM International in Journal of Forensic Sciences
- Vol. 46 (3) , 647-660
- https://doi.org/10.1520/jfs15018j
Abstract
The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR® Profiler Plus™ and AmpFlSTR COfiler™ (Applied Biosystems, Foster City, CA), GenePrint™ PowerPlex™ (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism® 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO® II Fluorescent Imaging Device, and the FluorImager™ were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.Keywords
This publication has 35 references indexed in Scilit:
- Population Data on the Thirteen CODIS Core Short Tandem Repeat Loci in African Americans, U.S. Caucasians, Hispanics, Bahamians, Jamaicans, and TrinidadiansJournal of Forensic Sciences, 1999
- Validation of Highly Polymorphic Fluorescent Multiplex Short Tandem Repeat Systems Using Two Generations of DNA SequencersJournal of Forensic Sciences, 1999
- TWGDAM Validation of the AmpFISTR™ Blue PCR Amplification Kit for Forensic Casework AnalysisJournal of Forensic Sciences, 1998
- The validation of a 7-locus multiplex STIR test for use in forensic caseworkInternational journal of legal medicine, 1996
- The validation of a 7-locus multiplex STIR test for use in forensic caseworkInternational journal of legal medicine, 1996
- Validation of highly discriminating multiplex short tandem repeat amplification systems for individual identificationElectrophoresis, 1996
- Validation and Population Studies of the Loci LDLR, GYPA, HBGG, D7S8, and Gc (PM loci), and HLA-DQα Using a Multiplex Amplification and Typing ProcedureJournal of Forensic Sciences, 1995
- Simple protocols for typing forensic biological evidence: Chemiluminescent detection for human DNA quantitation and restriction fragment length polymorphism (RELP) analyses and manual typing of polymerase chain reaction (PCR) amplified polymorphismsElectrophoresis, 1995
- DNA Extraction Strategies for Amplified Fragment Length Polymorphism AnalysisJournal of Forensic Sciences, 1994
- The validation of short tandem repeat (STR) loci for use in forensic caseworkInternational journal of legal medicine, 1994