Removal of EPI Nyquist ghost artifacts with two‐dimensional phase correction
Open Access
- 24 May 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (6) , 1247-1253
- https://doi.org/10.1002/mrm.20097
Abstract
Odd–even echo inconsistencies result in Nyquist ghost artifacts in the reconstructed EPI images. The ghost artifacts reduce the image signal-to-noise ratio and make it difficult to correctly interpret the EPI data. In this article a new 2D phase mapping protocol and a postprocessing algorithm are presented for an effective Nyquist ghost artifacts removal. After an appropriate k-space data regrouping, a 2D map accurately encoding low- and high-order phase errors is derived from two phase-encoded reference scans, which were originally proposed by Hu and Le (Magn Reson Med 36:166–171;1996) for their 1D nonlinear correction method. The measured phase map can be used in the postprocessing algorithm developed to remove ghost artifacts in subsequent EPI experiments. Experimental results from phantom, animal, and human studies suggest that the new technique is more effective than previously reported methods and has a better tolerance to signal intensity differences between reference and actual EPI scans. The proposed method may potentially be applied to repeated EPI measurements without subject movements, such as functional MRI and diffusion coefficient mapping. Magn Reson Med 51:1247–1253, 2004.Keywords
This publication has 16 references indexed in Scilit:
- Elimination of Nyquist ghosting caused by read‐out to phase‐encode gradient cross‐terms in EPIMagnetic Resonance in Medicine, 2002
- Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scanIEEE Transactions on Medical Imaging, 2001
- Optimized distortion correction technique for echo planar imagingMagnetic Resonance in Medicine, 2001
- Image-based ghost correction for interleaved EPIMagnetic Resonance in Medicine, 2001
- The effect of residual Nyquist ghost in quantitative echo-planar diffusion imagingMagnetic Resonance in Medicine, 1999
- High spatial resolution EPI using an odd number of interleavesMagnetic Resonance in Medicine, 1999
- Referenceless interleaved echo-planar imagingMagnetic Resonance in Medicine, 1999
- Correction for geometric distortion in echo planar images from B0 field variationsMagnetic Resonance in Medicine, 1995
- Image reconstruction for echo planar imaging with nonequidistant k‐space samplingMagnetic Resonance in Medicine, 1992