Prevention of Dislocation After Hip Arthroplasty
- 1 December 2001
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 393 (393) , 157-162
- https://doi.org/10.1097/00003086-200112000-00018
Abstract
Regarding dislocation after total hip arthroplasty, prevention is worth an ounce of cure. The current authors evaluated dislocation after total hip arthroplasty during the 26-year practice of one surgeon to identify potential variables that can contribute to the prevention of dislocation. Between 1970 and 1996, dislocation after total hip replacement occurred after 7.2% of primary hip arthroplasty procedures (298 of 4164 primary hip replacements) and 11.2% of revision hip arthroplasty procedures (90 of 803 revision hip replacements). Significant findings included an increase in dislocation when 22-mm modular femoral heads were used and a decrease in dislocation after revision for dislocation when constrained liners were used. An additional finding was that 26% of first time dislocations occurred more than 2 years after surgery. Concerning prevention of dislocation, small head modular femoral components should be used cautiously, and constrained liners should be considered in complex revision cases. Patients should be counseled concerning the potential for dislocation many years after their arthroplasty.Keywords
This publication has 18 references indexed in Scilit:
- Late dislocations after cementless total hip arthroplasty resulting from polyethylene wearThe Journal of Arthroplasty, 2000
- Extended Slide Trochanteric Osteotomy for Revision Total Hip Arthroplasty*Journal of Bone and Joint Surgery, 2000
- Practice Surveillance: A Practical Method to Assess Outcome and to Perform Clinical ResearchClinical Orthopaedics and Related Research, 1999
- Causes of and Treatment Protocol for Instability of Total Hip ReplacementClinical Orthopaedics and Related Research, 1998
- Relationship of Femoral Head and Acetabular Size to the Prevalence of DislocationClinical Orthopaedics and Related Research, 1998
- Salvage of Total Hip Instability With a Constrained Acetabular ComponentClinical Orthopaedics and Related Research, 1998
- Salvage of a Recurrently Dislocating Total Hip Prosthesis with Use of a Constrained Acetabular Component. A Retrospective Analysis of Fifty-six Cases*Journal of Bone and Joint Surgery, 1998
- Difficult Complications After Hip Joint ReplacementClinical Orthopaedics and Related Research, 1997
- Constrained acetabular componentsThe Journal of Arthroplasty, 1994
- Range of motion in contemporary total hip arthroplasty: The impact of modular head-neck componentsThe Journal of Arthroplasty, 1991