Rotary Blood Pump Flow Spontaneously Increases During Exercise Under Constant Pump Speed: Results of a Chronic Study
- 1 August 1999
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 23 (8) , 797-801
- https://doi.org/10.1046/j.1525-1594.1999.06426.x
Abstract
Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with the long‐term observation of calves implanted with centrifugal blood pumps (EVAHEART, Sun Medical Technology Research Corporation, Nagano, Japan). Two healthy female Jersey calves were implanted with devices in the left thoracic cavity. A total of 22 treadmill exercise tests were performed after the 50th postoperative day. During exercise, the following parameters were compared with conditions at rest: heart rate, blood pressure, central venous oxygen saturation (SvO2), pump speed, and pump flow. The pump flow in a cardiac cycle was analyzed by separating the systole and diastole. Compared to the base data, statistically significant differences were found in the following interrelated parameters: the heart rate (66.8 ± 5.2 vs. 106 ± 9.7 bpm), mean pump flow (4.8 ± 0.2 vs. 7.0 ± 0.3 L/min), and volume of pump flow in diastole (26.0 ± 1.8 vs. 13.5 ± 2.5 ml). During exercise, the volume of pump flow in systole was 3 times larger than that measured in diastole. Blood pressure, SvO2, and pump speed did not change significantly from rest to exercise. These results suggested that the mean pump flow depends on the systolic pump flow. Therefore, the increase in the mean pump flow during exercise under constant pump speed was caused by an increase in the heart rate.Keywords
This publication has 15 references indexed in Scilit:
- Surface Treated Large Bore Catheters With Silver Based Coatings Versus Untreated Catheters for Extracorporeal Detoxification MethodsAsaio Journal, 1998
- Design and Development Strategy for the Rotary Blood PumpArtificial Organs, 1998
- An Implantable Centrifugal Blood Pump with a Recirculating Purge System (Cool‐Seal System)Artificial Organs, 1998
- Development of the NimbudPittsburgh Axial Flow Left Ventricular Assist SystemArtificial Organs, 1997
- Effects of Exercise During Long-term Support With a Left Ventricular Assist DeviceCirculation, 1997
- CONTROL OF PRESSURE-FLOW RELATIONSHIP WITH A MAGNETICALLY SUSPENDED CENTRIFUGAL PUMP (MSCP) IN CHRONIC ANIMAL EXPERIMENTAsaio Journal, 1997
- A TOTALLY IMPLANTABLE CENTRIFUGAL BLOOD PUMP FOR LONG-TERM CIRCULATORY SUPPORTAsaio Journal, 1997
- Exercise Capacity Recovers Slowly But Fully in Patients With a Left Ventricular Assist DevicePublished by Wolters Kluwer Health ,1996
- Controller for an Axial Flow Blood PumpArtificial Organs, 1996
- Dynamic Systemic Vascular Resistance in a Sheep Supported with a Nimbus AxiPumpAsaio Journal, 1994