Photon migration through fetal head in utero using continuous wave, near infrared spectroscopy: clinical and experimental model studies
- 1 January 2000
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 5 (2) , 173-84
- https://doi.org/10.1117/1.429984
Abstract
Near infrared (NIR) measurements were made from the maternal abdomen (clinical studies) and laboratory tissue phantoms (experimental studies) to gain insight into photon migration through the fetal head in utero. Specifically, a continuous wave spectrometer was modified and employed to make NIR measurements at 760 and 850 nm, at a large (10 cm) and small (2.5/4 cm) source-detector separation, simultaneously, on the maternal abdomen, directly above the fetal head. A total of 19 patients were evaluated, whose average gestational age and fetal head depth, were 37 weeks +/- 3 and 2.25 cm +/- 0.7, respectively. At the large source-detector separation, the photons are expected to migrate through both the underlying maternal and fetal tissues before being detected at the surface, while at the short source-detector separation, the photons are expected to migrate primarily through the superficial maternal tissues before being detected. Second, similar NIR measurements were made on laboratory tissue phantoms, with variable optical properties and physical geometries. The variable optical properties were obtained using different concentrations of India ink and Intralipid in water, while the variable physical geometries were realized by employing glass containers of different shapes and sizes. Third, the NIR measurements, which were made on the laboratory tissue phantoms, were compared to the NIR measurements made on the maternal abdomen to determine which tissue phantom best simulates the photon migration path through the fetal head in utero. The results of the comparison were used to provide insight into the optical properties and physical geometry of the maternal and fetal tissues in the photon migration path.Keywords
This publication has 12 references indexed in Scilit:
- Practice Variation and the Risk of Low Birth Weight in a Public Prenatal Care ProgramMedical Care, 1997
- Photon migration in the presence of a single defect: a perturbation analysisApplied Optics, 1995
- The Continuing Challenge of Preterm DeliveryJAMA, 1995
- Frequency-domain reflectance for the determination of the scattering and absorption properties of tissueApplied Optics, 1991
- Prenatal and perinatal factors in the etiology of cerebral palsyThe Journal of Pediatrics, 1990
- Fetal assessment based on fetal biophysical profile scoringAmerican Journal of Obstetrics and Gynecology, 1990
- Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscleAnalytical Biochemistry, 1988
- An Assessment of the First Decade's Experience with Antepartum Fetal Heart Rate TestingAmerican Journal of Perinatology, 1988
- Antecedents of Cerebral PalsyNew England Journal of Medicine, 1986
- Nonstress Fetal Heart Rate TestingClinical Obstetrics and Gynecology, 1982