The variability of measuring sperm concentration and motility as determined by computer assisted image analysis and visual estimation
- 24 April 2009
- journal article
- research article
- Published by Hindawi Limited in Andrologia
- Vol. 25 (4) , 181-187
- https://doi.org/10.1111/j.1439-0272.1993.tb02707.x
Abstract
Systems of computer-assisted image processing (CAIP) offer good reproducibility and low intra-assay variability between replicate analyses of the same sample. The correlation between these values and those obtained by directly microscopic observation can be well demonstrated. The comparability between systems of different manufacturers is sufficient and satisfactory. Thus, they are well-suited for the routine work in the andrologic laboratory. Since sperm parameters are used for the prediction of male fertility, it is important to know whether computer-assisted analysis improves the predictive power as compared to visual estimation. In our study we compared the variation of semen parameters between two semen samples of the same individual taken in an interval of at least 3 months, by using the CAIP and visual methods. Significantly close correlations between the two values were obtained by both methods. Values of cell concentration showed the highest correlation in both methods (r = 0.75). The lowest correlation, but also statistically significant, was observed in the values of locally motile cells (r = 0.54 for CAIP and r = 0.30 for visual determination). Although apparently higher in CAIP within method correlation coefficients did not show statistically meaningful differences between both methods. We conclude from our study that if values of sperm concentration and motility as measured by CAIP are compared to those obtained by visual measurement, the first method is not superior to the latter in terms of retest reliability.Keywords
This publication has 12 references indexed in Scilit:
- Semen analysis and fertility prognosis in andrological patientsInternational Journal of Andrology, 1992
- Clinical Use and Misuse of Automated Semen AnalysisAnnals of the New York Academy of Sciences, 1991
- Does computerized image analysis of sperm movement enhance the predictive value of semen analysis for in-vitro fertilization results?International Journal of Andrology, 1989
- The long-term predictive value of the zona-free hamster ova sperm penetration assayFertility and Sterility, 1989
- Evaluation of Computerized Analysis of Sperm Movement Characteristics and Differential Sperm Tail Swelling Patterns in Predicting Human Sperm In Vitro Fertilizing CapacityJournal of Andrology, 1989
- Assessment of sperm motion characteristics from fertile and infertile men using a fully automated computer-assisted semen analyzerFertility and Sterility, 1989
- Measurement of spermatozoal motility over prolonged periods of time using image analysisComputers and Biomedical Research, 1988
- Quantitation of Specific Parameters of Motility in Large Numbers of Human Sperm by Digital Image Processing1Biology of Reproduction, 1988
- Computerized Sperm Motility and Application of Sperm CryopreservationArchives of Andrology, 1988
- SEMEN ANALYSES OF TWO HUNDRED FERTILE MENThe Lancet Healthy Longevity, 1938