Accurate determination of spin‐density and T1 in the presence of RF‐field inhomogeneities and flip‐angle miscalibration
- 1 October 1998
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 40 (4) , 592-602
- https://doi.org/10.1002/mrm.1910400412
Abstract
A method is presented for the accurate extraction of relative spin‐density (ρo) and spin‐lattice relaxation time (T1) in the presence of RF‐field inhomogeneities and flip‐angle miscalibration. The method requires collecting images at several flip‐angles with a three‐dimensional, spoiled steady‐state, gradient‐echo imaging sequence. Results show that the predominant effect of an overestimated flip‐angle is to shift the T1 estimate to a higher value, whereas reductions in the normalized RF‐field from unity cause ρo and T1 distributions to be skewed toward lower values. Phantom and in vivo results demonstrate that the proposed method overcomes both of these systematic errors. The method was shown to be valid for up to a 50% reduction in RF sensitivity. A self‐consistency argument was used to validate the absence of systematic errors in the extracted ρo and T1 values over a large number of voxels. This made it possible to obtain a very precise estimate of muscle T1 at 1.5 T, yielding a 95% confidence interval of (1077.7 ± 3.5) ms.Keywords
This publication has 22 references indexed in Scilit:
- Spin‐lattice relaxation time measurement by means of a TurboFLASH techniqueMagnetic Resonance in Medicine, 1993
- Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRIIEEE Transactions on Medical Imaging, 1993
- Modified iterative model based on data extrapolation method to reduce Gibbs ringingJournal of Magnetic Resonance Imaging, 1991
- Higher-order frequency dependence of radiofrequency penetration in planar, cylindrical, and spherical modelsJournal of Magnetic Resonance (1969), 1991
- In Vivo Brain Water Determination by T1 Measurements: Effect of Total Water Content, Hydration Fraction, and Field StrengthMagnetic Resonance in Medicine, 1991
- A k-space analysis of small-tip-angle excitationJournal of Magnetic Resonance (1969), 1989
- Reproducibility of relaxation and spin-density parameters in phantoms and the human brain measured by MR imaging at 1.5TMagnetic Resonance in Medicine, 1986
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986
- A new look at the method of variable nutation angle for the measurement of spin-lattice relaxation times using fourier transform NMRJournal of Magnetic Resonance (1969), 1977
- Tumor Detection by Nuclear Magnetic ResonanceScience, 1971