Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
- 1 January 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 22 (1) , 139-152
- https://doi.org/10.1097/00004728-199801000-00027
Abstract
We sought to describe and validate an automated image registration method(AIR 3.0) based on matching of voxel intensities. Different cost functions, different minimization methods, and various sampling, smoothing, and editing strategies were compared. Internal consistency measures were used to place limits on registration accuracy for MRI data, and absolute accuracy was measured using a brain phantom for PET data. All strategies were consistent with subvoxel accuracy for intrasubject, intramodality registration. Estimated accuracy of registration of structural MRI images was in the 75 to 150 μm range. Sparse data sampling strategies reduced registration times to minutes with only modest loss of accuracy. The registration algorithm described is a robust and flexible tool that can be used to address a variety of image registration problems. Registration strategies can be tailored to meet different needs by optimizing tradeoffs between speed and accuracy.Keywords
This publication has 17 references indexed in Scilit:
- Comparison and Evaluation of Retrospective Intermodality Brain Image Registration TechniquesJournal of Computer Assisted Tomography, 1997
- Convolution-based interpolation for fast, high-quality rotation of imagesIEEE Transactions on Image Processing, 1995
- Detection of Subtle Brain Changes Using Subvoxel Registration and Subtraction of Serial MR ImagesJournal of Computer Assisted Tomography, 1995
- A Registration and Interpolation Procedure for Subvoxel Matching of Serially Acquired MR ImagesJournal of Computer Assisted Tomography, 1995
- Motion detection and correction in functional MR imagingHuman Brain Mapping, 1995
- Quantitative Comparisons of Image Registration Techniques Based on High-Resolution MRI of the BrainJournal of Computer Assisted Tomography, 1994
- Avoidance of additional aliasing in multipass image rotationsIEEE Transactions on Image Processing, 1994
- MRI-PET Registration with Automated AlgorithmJournal of Computer Assisted Tomography, 1993
- Rapid Automated Algorithm for Aligning and Reslicing PET ImagesJournal of Computer Assisted Tomography, 1992
- The Chirp z-Transform Algorithm and Its ApplicationBell System Technical Journal, 1969