Interlist Equivalency of the CID W-22 Word Lists Presented in Quiet and in Noise
- 1 March 1983
- journal article
- research article
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 4 (2) , 91-97
- https://doi.org/10.1097/00003446-198303000-00005
Abstract
The interlist equivalency of the CID W-22 word lists administered in quiet and in a background of noise was investigated using 48 normal-hearing subjects. All four word lists were administered at 20 dB SL in quiet and in the presence of a multitalker babble (0 dB signal-to-noise ratio). In the statistical analyses, word performance and subject performance were used as the dependent measures. The results indicated that: (1) the lists are equivalent when administered in quiet; (2) the lists are not equivalent when administered in a background of multitalker babble; (3) the addition of noise changes the relationship among the word lists in a nonpredictive manner; and (4) the addition of noise changes the level of difficulty of some words of each list to a greater degree, relative to the other words. The results are discussed relative to their implications for hearing evaluation and hearing aid evaluation procedures.Keywords