Investigation of on-line reversed-phase liquid chromatography–gas chromatography–mass spectrometry as a tool for the identification of impurities in drug substances
- 1 January 1996
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 121 (1) , 61-66
- https://doi.org/10.1039/an9962100061
Abstract
The potential of on-line reversed-phase (RP) LC–GC–MS for the identification of impurities in pharmaceutical products has been investigated. The technical aspects of the system were studied using the potential drug eltoprazine as test compound. After LC separation on a 2 mm id RPLC column, using 5 mmol l–1 methanesulfonic acid in acetonitrile–water (84 + 16 v/v) as eluent, the eltoprazine-containing fraction of 200 µl was introduced on-line into the GC–MS, the mass spectrometer being a magnetic sector instrument. Before this introduction, the methanesulfonic acid was removed on-line from the LC eluent via an anion-exchange membrane. Most of the solvent introduced into the GC–MS was evaporated via a solvent vapour exit installed in front of the capillary GC column. As an application, impurity profiling was performed on the drug substance mebeverine which contained mebeverine amine as test impurity. The addition of acetonitrile was necessary before introduction into the GC; therefore only about 10% v/v of the mebeverine amine LC peak was transferred to the GC–MS. Nevertheless, electron impact and chemical ionization spectra of the impurity could be obtained at a level of 0.1% with respect to the drug.Keywords
This publication has 11 references indexed in Scilit:
- Reversed‐phase liquid chromatography coupled on‐line with capillary gas chromatography II. Use of a solvent vapor exit to increase introduction volumes and introduction rates into the gas chromatographJournal of Microcolumn Separations, 1994
- Pharmaceutical application of LC-MS. 1 — Characterization of a famotidine degradates in a package screening study by LC-APCI MSJournal of Pharmaceutical and Biomedical Analysis, 1994
- Elucidation of the structure of drug degradation products by on-line coupled reversed phase HPLC-GC-MS and on-line derivatizationJournal of High Resolution Chromatography, 1993
- On-line coupled reversed-phase high-performance liquid chromatography—gas chromatography—mass spectrometry: A powerful tool for the identification of unknown impurities in pharmaceutical productsJournal of Chromatography A, 1992
- Coupled LC‐GC‐MS for on‐line clean‐up, separation, and identification of chlorinated polycyclic aromatic hydrocarbons at picogram levels in urban airJournal of High Resolution Chromatography, 1992
- Reversed-phase liquid chromatography coupled on-line with capillary gas chromatographyJournal of Chromatography A, 1991
- On-line coupling of liquid chromatography, capillary gas chromatography and mass spectrometry for the determination and identification of polycyclic aromatic hydrocarbons in vegetable oilsChromatographia, 1991
- Biochemical applications of liquid chromatography-mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1989
- On-line microbore high-performance liquid chromatography—capillary gas chromatography—mass spectrometryJournal of Chromatography A, 1987
- Liquid chromatography mass spectrometry in the pharmaceutical industry: Objectives and needsJournal of Chromatography A, 1982