Determination of platinum, rhodium and palladium in exhaust fumes
- 1 January 1999
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 14 (8) , 1163-1169
- https://doi.org/10.1039/a901516g
Abstract
With the introduction of catalytic converters for reducing emissions of CO, NO x and HC, a higher concentration of Pt, Pd and Rh is being observed in environmental samples. These platinum group elements (PGE) are the main active components of catalytic converters and they are mainly released as a result of surface abrasion of the catalyst during car operation. The present work reports the procedure employed for sampling, mineralization and determination of PGE by quadrupole ICP-MS in three different types of catalysts. Whole raw exhaust fumes were collected directly from the end of the exhaust pipe following the 91441 extra urban drive cycle (EUDC) using a newly developed sampling device. The sampling procedure allows the further differentiation between a soluble and particulate (insoluble) sample fraction. The release of pollutants such as Hf, Cu, Y, Rb, Sr and Pb present in the catalyst washcoat or in the fuel was also monitored since these elements cause spectral interferences in the determination of PGE. These spectral interferences, 179 Hf 16 O + on 195 Pt, 40 Ar 65 Cu + and 89 Y 16 O + on 105 Pd and 40 Ar 63 Cu + , 87 Rb 16 O + , 87 Sr 16 O + and 206 Pb 2+ on 103 Rh, were considered and mathematically corrected. The sampling procedure was applied to quantify the PGE released from two different types of fresh gasoline catalyst (Pt/Pd/Rh and Pd/Rh), a diesel catalyst (Pt only) and a 18 000 km aged Pt/Pd/Rh gasoline catalyst. Most of the released PGE is in particulate form (Pt >95%, Pd >85% and Rh >90%). Release was found to vary from catalyst to catalyst and between samples of the same catalyst. The determination of PGE in the exhaust fumes shows that they are released at the ng km –1 level.Keywords
This publication has 9 references indexed in Scilit:
- Verteilung von Platingruppenelementen (PGE) in den Umweltkompartimenten Boden, Schlamm, Straßenstaub, Straßenkehrgut und WasserUmweltwissenschaften und Schadstoff-Forschung, 1997
- Investigation of HfO+ interference in the determination of platinum in a catalytic converter (cordierite) by inductively coupled plasma mass spectrometryTalanta, 1997
- Determination of Vanadium, Rhodium and Platinum in Automotive Catalytic Converters Using Inductively Coupled Plasma Mass Spectrometry With Spark AblationJournal of Analytical Atomic Spectrometry, 1997
- Catalytic automotive exhaust aftertreatmentProgress in Energy and Combustion Science, 1997
- Particle analysis of car exhaust by ETV-ICP-MSAnalytical and Bioanalytical Chemistry, 1996
- Spectral and non-spectral interferences in inductively coupled plasma mass-spectrometryMicrochimica Acta, 1995
- Interferences in inductively coupled plasma mass spectrometry. A reviewJournal of Analytical Atomic Spectrometry, 1993
- Determination of platinum emissions from a three-way catalyst-equipped gasoline engineAtmospheric Environment. Part A. General Topics, 1992
- Radiometric Determination of Platinum and Palladium Attrition from Automotive CatalystsIEEE Transactions on Nuclear Science, 1977