Factors Influencing Pneumothorax Rate at Lung Biopsy: Are Dwell Time and Angle of Pleural Puncture Contributing Factors?
- 1 February 2001
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 218 (2) , 491-496
- https://doi.org/10.1148/radiology.218.2.r01fe33491
Abstract
To study factors that may influence pneumothorax and chest tube placement rate, especially needle dwell time and pleural puncture angle. In 159 patients, 160 coaxial computed tomography (CT)-guided lung biopsies were performed. Dwell time, the time between pleural puncture and needle removal, was calculated. The smallest angle of the needle with the pleura ("needle-pleural angle") was measured. These and other variables were correlated with pneumothorax and chest tube rates. One hundred fifty biopsies were included. There were 58 (39%) pneumothoraces (14 noted only at CT), with eight (5%) biopsies resulting in chest tube placement. Longer dwell times (mean, 29 minutes; range, 12-66 minutes) did not correlate with pneumothoraces (P =.81). Smaller needle-pleural angles (< 80 degrees) [corrected], decreased forced expiratory volume in 1 second to vital capacity ratio (<50%), lateral pleural puncture, and lesions along fissures were associated with higher [corrected] pneumothorax rates (P <.05). Emphysema along the needle path, pulmonary function tests showing ventilatory obstruction, and lesions along fissures predisposed patients to chest tube placement (P <.05). Pleural thickening and prior surgery were associated with lower pneumothorax rates (P <.05). Longer dwell times do not correlate with pneumothorax and should not influence the decision to obtain more biopsy samples. A shallow pleural puncture angle may increase the pneumothorax rate.Keywords
This publication has 18 references indexed in Scilit:
- Transthoracic Needle Aspiration Biopsy: Variables That Affect Risk of PneumothoraxRadiology, 1999
- Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.American Journal of Roentgenology, 1999
- Technical aspects of needle aspiration lung biopsy: a personal perspective.Radiology, 1998
- Predicting the Rates of Success and Complications of Computed Tomography-Guided Percutaneous Core-Needle Biopsies of the Thorax from the Findings of the Preprocedure Chest Computed Tomography ScanJournal of Thoracic Imaging, 1998
- “Oblique path”—The optimal needle path for computed tomography-guided biopsy of small subpleural lesionsCardioVascular and Interventional Radiology, 1996
- Needle aspiration lung biopsy: reevaluation of the blood patch technique in an equine model.Radiology, 1995
- CT gantry tilt: utility in transthoracic fine-needle aspiration biopsy. Work in progress.Radiology, 1993
- Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: report of 55 cancer patients and metaanalysis of the literature.American Journal of Roentgenology, 1993
- Difficult thoracic lesions: CT-guided biopsy experience in 150 cases.Radiology, 1988
- Prediction of Pneumothorax Rate in Percutaneous Needle Aspiration of the LungChest, 1988